gf6800p0001lf

Temperature-controlled cup holder, function

ประเภท gf · หัวข้อ 68.00 · เวอร์ชัน 0100 · 2013-04-30

ใช้กับ: MODEL 222 with CODE 224 (Rear individual seat design)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 68 Interior equipment › 68.00 General — ซีรีส์ 222

GF68.00-P-0001LF

Temperature-controlled cup holder, function

9.4.13

MODEL

222

with CODE 224 (Rear individual seat design)

Temperature-controlled cup holder, function

N10/8

Rear SAM control unit

N73

Electronic ignition switch control unit

K40/5

Rear fuse and relay module

K40/5kU

2nd seat row cup holder and power outlet relay

R5/3

Rear cup holder

R5/3s1

Rear cup holder button

CAN B

Interior CAN

P68.00-6877-81

Function requirements, general

Circuit 15R ON

The electronic ignition lock control unit sends the status of circuit 15 via interior CAN to the rear SAM control unit.

Temperature-controlled cup holder, general

Beverages can be cooled or heated with the cup holder. It is possible to heat to approx. T = 58 °C and cool to approx. T = 3 °C.

The main cup holder components are:

Cup holder button

Heating/cooling element (Peltier element)

Fan

Temperature sensor

Before switching on the circuit the cupholder is supplied with power 15R via the cupholder relay and sockets for the 2nd seat row in the rear fuse and relay module.

The cup holder function comprises the following partial functions:

Function sequence for cooling

Function sequence for heating

Function sequence for display of fault messages

Function sequence for cooling

The cooling function is activated when the cup holder button is actuated once. Active cooling is indicated by a blue LED flashing.

The cooling procedure takes places within the following time-dependent cooling output for a 0.33 l beverage can as an example:

Within t = 30 min from T = 21 °C to approx. T = 15 °C

Within t = 60 min from T = 21 °C to approx. T = 10 °C

Within t = 120 min from T = 21 °C to approx. T = 5 °C

The cooling procedure can be interrupted when the LED on the cup holder button is pressed again before the LED goes out.

Function sequence for heating

The heating function is activated when the cup holder button is pressed twice. Active heating is indicated by a red LED flashing.

The heating procedure takes places within the following time-dependent heating output for a 0.33 l beverage can as an example:

Within t = 30 min from T = 21 °C to approx. T = 30 °C

Within t = 60 min from T = 21 °C to approx. T = 40 °C

Within t = 120 min from T = 21 °C to approx. T = 50 °C

The residual heat indicator lamp signals increased temperature to the vehicle passengers starting at a temperature of approx. T = 40 °C .

The heating procedure can be interrupted when the LED on the cup holder button is pressed again before the LED goes out.

Function sequence for display of fault messages

Errors occurring during operation are indicated by the corresponding LED flashing:

Double flashing:

The cup holder button is inhibited.

Flashing three times:

Malfunction in cupholder heating/cooling element. Disconnect cup holder from on-board electrical system and reconnect. If the error occurs again, the heating/cooling system is defective.

Flashing four times:

Malfunction in cup holder temperature sensor. Disconnect cup holder from on-board electrical system and reconnect. If this error occurs again, the temperature sensor is defective.

Overview of system components of comfort heating systems

GF91.30-P-9990LF

เอกสารที่อ้างถึง