Front axle level control valve unit, component description

ประเภท gf · หัวข้อ 32.33 · เวอร์ชัน 0100 · 2013-10-10

ใช้กับ: MODEL 967

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 32 Suspension › 32.33 Ground clearance compensator (NR/ENR) — ซีรีส์ 967

GF32.33-W-3121K

Front axle level control valve unit, component description

18.7.13

MODEL

967

Front axle level control valve unit, component description

Location

Shown on vehicle with code A1A (Air-sprung front axle)

Y20

Front axle level control valve unit

W32.33-2091-81

The front axle level control valve unit (Y20) is installed in the center on the frame crossmember in the area of the fuel tank.

Task

The front axle level control valve unit (Y20) converts the control signals from the level control (CLCS) control unit (A26) into air-admission and venting procedures for the sleeve air springs (43.01) of the front axle.

Front axle level control valve unit, component description

Body

Components/pneumatic connections

3

Atmospheric connection (venting)

11

Energy supply (air suspension reservoir pressure)

22

Energy outflow (right sleeve air spring)

23

Energy outflow (left sleeve air spring)

ANV 1

Pneumatic starting-off valve 1 (electrically actuated)

ANV 2

Pneumatic starting-off valve 2 (electrically actuated)

DR

Throttle

F

Filter

WV

3/2-way valve

WV1

2/2-way valve 1

WV2

2/2-way valve 2

Y20

Front axle level control valve unit

W32.33-2065-11

The 2/2-way valves (WV1, WV2) or the 3/2-way valve (WV ) are directly connected to the level control control unit (CLCS) (A26).

Function

1 Increase in pressure at energy outflows (22, 23)

Pneumatic starting-off valve 1 (electrically actuated) (ANV 1) of the 3/2-way valve (WV) is energized which causes the 3/2-way valve (WV) to switch to the flow-through position. The pressure present at the energy supply (11) is fed to the 2/2-way valves (WV 1 and WV2) which are in the closed position. Pneumatic starting-off valve 2 (electrically actuated) (ANV 2) of the 2/2-way valves (WV 1 and WV2) is then energized and the 2/2-way valves (WV 1 and WV 2) switch to the flow-through position. The pressure present at the input of the 2/2-way valves (WV 1 and WV WV2) is fed to the energy outflows (22 and 23). If the desired pressure is not achieved at the energy outflows (22 and 23), the pneumatic starting-off valve 2 (electrically actuated) (ANV 2) is no longer energized and the 2/2-way valves (WV 1 and WV 2) switch back to locking position. The pressure present at the energy outflows (22 and 23) is held.

2 Reduction in pressure at energy outflows (22, 23)

In order to reduce the pressure at the energy outflows (22 and 23), pneumatic starting-off valve 1 (electrically actuated) (ANV 1) is no longer energized and the 3/2-way valve (WV) switches back to its starting position. Pneumatic starting-off valve 2 (electrically actuated) (ANV 2) of the 2/2-way valves (WV 1 and WV2) is energized and the 2/2-way valves (WV 1 and WV 2) switch to the flow-through position. The pressure present at the energy outflows (22 and 23) is then vented via the 2/2-way valve 1 (WV 1) or 2/2-way valve 2 (WV 2), the 3/2-way valve (WV) and the atmosphere connection (3). If the desired pressure is not achieved at the energy outflows (22 and 23), the pneumatic starting-off valve 2 (electrically actuated) (ANV 2) is no longer energized and the 2/2-way valves (WV 1 and WV 2) switch back to locking position. The pressure present at the energy outflows (22 and 23) is held.