gf1440b3007b

SCR compressed air pressure sensor, component description

ประเภท gf · หัวข้อ 14.40 · เวอร์ชัน 0200 · 2016-02-12

ใช้กับ: Cumbustion engine 457.9 with Vehicle 382.15# #D, 634.0## #D with CODE MS5 (BlueTec 5)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 1 Engine › 14 Exhaust manifold, engine brake, emission control system › 14.40 Exhaust aftertreatment, AdBlue — ซีรีส์ 382 (รุ่น 15*) · ซีรีส์ 634 (รุ่น 0**)

EinPAS 15 Engine › 15.40 Exhaust system/exhaust aftertreatment › 15.40.12 Sensor/switch/wiring harness — ซีรีส์ 382 (รุ่น 15*) · ซีรีส์ 634 (รุ่น 0**)

ใช้กับเครื่องยนต์/เกียร์ด้วย: 457 9**

GF14.40-B-3007B

SCR compressed air pressure sensor, component description

12.02.16

Cumbustion engine 457.9 with Vehicle 382.15# #D, 634.0## #D with CODE MS5 (BlueTec 5)

SCR compressed air pressure sensor, component description

B14.40-0016-08

1 Metering unit

Arrangement

The compressed air pressure sensor (4) is fastened to the outside of the metering unit (1). The metering unit (1) is located close to the last cylinder head cylinder.

4 SCR (17B06) compressed air pressure sensor

Task

The compressed air pressure sensor (4) captures the AdBlue pressure at a measuring point inside the metering unit (1) and transmits the information to the engine control module (MR), as an electrical tension signal.

SCR compressed air pressure sensor, component description

B14.40-0026-11

Composition

The compressed air pressure sensor (4) consists of a threaded stainless steel housing and an electrical connector.

The inside of the compressed air pressure sensor contains, as a measuring element, a silicon membrane fitted with measuring strips. These measuring strips are electrical resistors that, during their expansion, modify their resistance (piezoresistive principle). The compressed air pressure sensor (4) is fitted with a drilling, through which the compressed air can penetrate up to the membrane. The compressed air pressure sensor (4) is an active sensor. i.e., it is supplied with a tension.

Function

The air actuating on the compressed air pressure sensor (4), presses the internal membrane. This pressure that causes the membrane, when expanding, to modify its electrical resistance on the measuring strips. With these pressure alterations, occurs the increase or decrease of the measuring strips resistance

The variations of electrical resistance are transmitted in defined intervals as analog signals to the control module (MR).

The control module (MR) calculates the corresponding pressure, starting from the resistance values.