Air conditioning |
Number | Designation | Model 118, 164, 166, 167, 169, 171, 177, 190, 197, 199, 204, 205, 206, 207, 209, 211, 212, 216, 218, 219, 221, 230, 238, 240, 243, 245, 247, 251, 253, 257, 290, 292, 293 | Model 213, 217, 222 | ||
BE83.30-P-1001-04A | Pressure drop in refrigerant circuit filled with test gas | Test pressure | bar | 15 | 90 |
Test period | h | 4 | 4 | ||
Permissible fluctuation of ambient temperature | °C | 2 | 2 | ||
Pressure drop | bar | 0 | <1 | ||
BE83.30-P-1002-04A | Preliminary test for pressure drop test | Test pressure | bar | - | 50 |
Test period | min | - | 1 | ||
Pressure drop | bar | - | 0 |
Air conditioning |
Number | Designation | Model 463 | Model 223 | ||
BE83.30-P-1001-04A | Pressure drop in refrigerant circuit filled with test gas | Test pressure | bar | 15 | 15 |
Test period | h | 4 | 4 | ||
Permissible fluctuation of ambient temperature | °C | 2 | 2 | ||
Pressure drop | bar | 0 | 0 | ||
BE83.30-P-1002-04A | Preliminary test for pressure drop test | Test pressure | bar | - | - |
Test period | min | - | - | ||
Pressure drop | bar | - | - |