Air conditioning system temperature sensor check values |
Number | Designation | Model 129 | Model 140 | ||
BE83.30-P-1001-01A | Evaporator temperature sensor resistance value, at ambient temperature | 0 °C | kΩ | 8,1...9,9 | 8,1...9,9 |
5 °C | kΩ | 6,3...7,7 | 6,3...7,7 | ||
10 °C | kΩ | 5,0...6,0 | 5,0...6,0 | ||
15 °C | kΩ | 4,0...4,6 | 4,0...4,6 | ||
20 °C | kΩ | 3,1...3,9 | 3,1...3,9 | ||
25 °C | kΩ | 2,4...3,0 | 2,4...3,0 | ||
30 °C | kΩ | 1,9...2,3 | 1,9...2,3 | ||
35 °C | kΩ | 1,6...2,0 | 1,6...2,0 | ||
40 °C | kΩ | 1,4...1,6 | 1,4...1,6 | ||
BE83.30-P-1002-01A | Outside air temperature sensor, resistance value at ambient temperature | 15 °C | kΩ | 4,0...6,0 | 4,0...6,0 |
20 °C | kΩ | 3,1...3,9 | 3,1...3,9 | ||
25 °C | kΩ | 2,4...3,0 | 2,4...3,0 | ||
30 °C | kΩ | 1,9...2,3 | 1,9...2,3 | ||
35 °C | kΩ | 1,6...2,0 | 1,6...2,0 | ||
40 °C | kΩ | 1,4...1,6 | 1,4...1,6 | ||
45°C | kΩ | 1,1...1,3 | 1,1...1,3 |
Air conditioning system temperature sensor check values |
Number | Designation | Model 202 | ||
BE83.30-P-1001-01A | Evaporator temperature sensor resistance value, at ambient temperature | 0 °C | kΩ | 8,1...9,9 |
5 °C | kΩ | 6,3...7,7 | ||
10 °C | kΩ | 5,0...6,0 | ||
15 °C | kΩ | 4,0...4,6 | ||
20 °C | kΩ | 3,1...3,9 | ||
25 °C | kΩ | 2,4...3,0 | ||
30 °C | kΩ | 1,9...2,3 | ||
35 °C | kΩ | 1,6...2,0 | ||
40 °C | kΩ | 1,4...1,6 | ||
BE83.30-P-1002-01A | Outside air temperature sensor, resistance value at ambient temperature | 15 °C | kΩ | 4,0...6,0 |
20 °C | kΩ | 3,1...3,9 | ||
25 °C | kΩ | 2,4...3,0 | ||
30 °C | kΩ | 1,9...2,3 | ||
35 °C | kΩ | 1,6...2,0 | ||
40 °C | kΩ | 1,4...1,6 | ||
45°C | kΩ | 1,1...1,3 |