Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1001-01A | Battery capacity 12 Ah | Cold cranking amps | As per EN | A | 170 |
BE54.10-P-1002-01A | Battery capacity 30 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 90 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 540 | ||
BE54.10-P-1003-01A | Battery capacity 35 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 100 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 520 | ||
BE54.10-P-1004-01A | Battery capacity 42 Ah | Cold cranking amps | As per EN | A | 340 |
BE54.10-P-1005-01A | Battery capacity 46 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 140 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 420 | ||
BE54.10-P-1006-01A | Battery capacity 60 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 660 |
BE54.10-P-1007-01A | Battery capacity 60 Ah | Cold cranking amps | As per EN | A | 510 |
BE54.10-P-1008-01A | Battery capacity 61 Ah | Cold cranking amps | As per EN | A | 540 |
BE54.10-P-1009-01A | Battery capacity 62 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 190 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 480 | ||
BE54.10-P-1010-01A | Battery capacity 70 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 720 |
BE54.10-P-1011-01A | Battery capacity 74 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 265 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 680 | ||
BE54.10-P-1012-01A | Battery capacity 80 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 800 |
BE54.10-P-1013-01A | Battery capacity 84 Ah | Cold cranking amps | As per EN | A | 700 |
BE54.10-P-1014-01A | Battery capacity 90 Ah VRLA | Cold cranking amps | As per EN | A | 950 |
BE54.10-P-1015-01A | Battery capacity 95 Ah VRLA | Cold cranking amps | As per EN | A | 850 |
BE54.10-P-1016-01A | Battery capacity 100 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 300 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 760 | ||
BE54.10-P-1017-01A | Battery capacity 12 Ah | Cold cranking amps | As per EN | A | 200 |
BE54.10-P-1018-01A | Battery capacity 105 Ah | Cold cranking amps | As per EN | A | 950 |
BE54.10-P-1019-01A | Battery capacity 78 Ah li-ion | Cold cranking amps | As per EN | A | 550 |
BE54.10-P-1020-01A | Battery capacity 10 Ah VRLA | Cold cranking amps | As per EN | A | 170 |
BE54.10-P-1021-01A | Battery capacity 92 Ah VRLA/AGM | Cold cranking amps | As per EN | A | 850 |