MODEL | ALL |
Battery/power supply test and adjustment values |
Number | Designation | MODEL ALL | |||
BE54.10-N-1001-01A | Battery capacity 46Ah | Cold test current | As per DIN | A | 250 |
As per EN | A | 420 | |||
BE54.10-N-1002-01A | Battery capacity 60 Ah | Cold test current | As per DIN | A | 300 |
As per EN | A | 510 | |||
BE54.10-N-1003-01A | Battery capacity 60 Ah AGM battery | Cold test current | As per DIN | A | 400 |
As per EN | A | 680 | |||
BE54.10-N-1004-01A | Battery capacity 62 Ah | Cold test current | As per DIN | A | 280 |
As per EN | A | 480 | |||
BE54.10-N-1005-01A | Battery capacity 66 Ah | Battery test at 20 °C | Acid density (battery charged) | kg/dm 3 | 1,28 |
Acid density during status test | kg/dm 3 | 1,24 | |||
Permissible deviation of individual cells | kg/dm 3 | 0,04 | |||
Cold test current | As per DIN | A | 300 | ||
As per EN | A | 510 | |||
BE54.10-N-1006-01A | Battery capacity 70 Ah AGM battery | Cold test current | As per DIN | A | 450 |
As per EN | A | 760 | |||
BE54.10-N-1007-01A | Battery capacity 74 Ah | Battery test at 20 °C | Acid density (battery charged) | kg/dm 3 | 1,28 |
Acid density during status test | kg/dm 3 | 1,24 | |||
Permissible deviation of individual cells | kg/dm 3 | 0,04 | |||
Cold test current | As per DIN | A | 400 | ||
As per EN | A | 680 | |||
BE54.10-N-1008-01A | Battery capacity 84 Ah | Cold test current | As per DIN | A | 420 |
As per EN | A | 700 | |||
BE54.10-N-1009-01A | Battery capacity 88 Ah | Battery test at 20 °C | Acid density (battery charged) | kg/dm 3 | 1,28 |
Acid density during status test | kg/dm 3 | 1,24 | |||
Permissible deviation of individual cells | kg/dm 3 | 0,04 | |||
Cold test current | As per DIN | A | 400 | ||
As per EN | A | 680 | |||
BE54.10-N-1010-01A | Battery capacity 90 Ah AGM battery | Cold test current | As per DIN | A | 580 |
As per EN | A | 950 | |||
BE54.10-N-1011-01A | Battery capacity 95 Ah AGM battery | Cold test current | As per DIN | A | 520 |
As per EN | A | 850 | |||
BE54.10-N-1012-01A | Battery capacity 100 Ah | Battery test at 20 °C | Acid density (battery charged) | kg/dm 3 | 1,28 |
Acid density during status test | kg/dm 3 | 1,24 | |||
Permissible deviation of individual cells | kg/dm 3 | 0,04 | |||
Cold test current | As per DIN | A | 450 | ||
As per EN | A | 760 | |||
BE54.10-N-1013-01A | Battery capacity 115 Ah | Cold test current | As per DIN | A | 380 |
As per EN | A | 640 | |||
BE54.10-N-1014-01A | Battery capacity 125 Ah | Cold test current | As per DIN | A | 430 |
As per EN | A | 720 | |||
BE54.10-N-1015-01A | Battery capacity 135 Ah | Cold test current | As per DIN | A | 420 |
As per EN | A | 680 | |||
BE54.10-N-1016-01A | Battery capacity 165 Ah | Cold test current | As per DIN | A | 540 |
As per EN | A | 900 | |||
BE54.10-N-1017-01A | Battery capacity 200 Ah | Cold test current | As per DIN | A | 630 |
As per EN | A | 1050 | |||
BE54.10-N-1018-01A | Battery capacity 220 Ah | Cold test current | As per DIN | A | 600 |
As per EN | A | 1000 | |||
BE54.10-N-1019-01A | Battery capacity 225 Ah | Cold test current | As per DIN | A | 680 |
As per EN | A | 1150 |