Check values for retarder (hydraulic) |
Number | Designation | Model 800 | MODEL 963, 964 with CODE B3H (Secondary water retarder) | ||
BE43.30-N-1001-01D | Specified value for actuating pressure | Brake stage 0 | bar | 0,0 | 0,0 |
Brake stage 1 | bar | 1,25...1,75 | 1,25...1,75 | ||
Brake stage 2 | bar | 1,75...2,25 | 1,75...2,25 | ||
Brake stage 3 | bar | 2,75...3,25 | 2,75...3,25 | ||
Brake stage 4 | bar | 3,25...3,75 | 3,25...3,75 | ||
Brake stage 5 | bar | 3,95...4,45 | 3,95...4,45 | ||
BE43.30-N-1002-01D | Specified value for internal resistance of coolant temperature sensor | Coolant temperature 20 (10) °C | Ω | 1039...1117 | 1039...1117 |
Coolant temperature 60 (10) °C | Ω | 1194...1271 | 1194...1271 | ||
Coolant temperature 80 (10) °C | Ω | 1271...1347 | 1271...1347 | ||
BE43.30-N-1003-01D | Vacuum test in working chamber of retarder | Test vacuum | mbar | -600 | -600 |
Test duration | min | 10 | 10 | ||
Max. vacuum reduction | mbar | 100 | 100 | ||
BE43.30-N-1004-01D | Distance from top edge of regulation valve to top edge of damping sleeve | mm | 28 (1) | 28 (1) | |
BE43.30-N-1005-01D | Test pressure | bar | 0,8 | 0,8 | |
BE43.30-N-1006-01D | Test pressure for seals in rotor housing | Test pressure | bar | 2,5 | 2,5 |
Test duration | min | 10 | 10 | ||
Max. pressure loss | bar | 0,1 | 0,1 | ||
BE43.30-N-1007-01D | Permissible pump tilt clearance for side duct | mm | 0,05...0,27 | 0,05...0,27 | |
BE43.30-N-1008-01D | Dimension of valve ball in coolant check valve | mm | 8,0...10,2 | 8,0...10,2 | |
BE43.30-N-1009-01D | Dimension of drive cams of side duct pipe | mm | 15...21 | 15...21 | |
BE43.30-N-1010-01D | Residual water quantity in retarder | ml | 250...700 | 250...700 |