MODEL | 375.4, 930, 932, 933, 934, 944, 950, 952, 953, 954 |
with CODE BA9 (Voith secondary retarder R 115) | |
without CODE BA1 (Performance-optimized Voith retarder) |
Check values for retarder (hydraulic) |
Number | Designation | MODEL 375.4, 930, 932, 933, 934, 944, 950, 952, 953, 954 with CODE BA9 (Voith secondary retarder R 115) | |
BE43.30-N-1001-01A | Specified value for float weight | g | 10...12 |
BE43.30-N-1002-01A | Specified value for test water temperature | °C | 70 |
BE43.30-N-1003-01A | Specified value for test air pressure | bar | 10 |
BE43.30-N-1004-01A | Specified value for actuating pressure | bar | 2,7...3,0 |
BE43.30-N-1005-01A | Specified value for static pump pressure | bar | 2,7...3,0 |
BE43.30-N-1006-01A | Specified value for control current / proportional current | mA | 534...546 |