MODEL | 460 |
Test values for ALB controller |
Number | Designation | MODEL 460 | MODEL 460 | |||
BE42.80-P-1001-01A | Output pressure of ALB controller (input pressure ALB controller 100 bar) with rear axle load (from 900 kg to 1500 kg) | 900 kg | Specified pressure | bar | 41 (2) | 44 (2) |
1000 kg | Specified pressure | bar | 47 (2) | 50 (2) | ||
1100 kg | Specified pressure | bar | 52 (2) | 55 (2) | ||
1200 kg | Specified pressure | bar | 58 (2) | 59 (2) | ||
1300 kg | Specified pressure | bar | 63 (2) | 62 (2) |
Test values for ALB controller |
Number | Designation | MODEL 460 | MODEL 460 | |||
BE42.80-P-1001-01A | Output pressure of ALB controller (input pressure ALB controller 100 bar) with rear axle load (from 900 kg to 1500 kg) | 900 kg | Specified pressure | bar | 40 (2) | 43 (2) |
1000 kg | Specified pressure | bar | 47 (2) | 50 (2) | ||
1100 kg | Specified pressure | bar | 52 (2) | 55 (2) | ||
1200 kg | Specified pressure | bar | 58 (2) | 57 (2) | ||
1300 kg | Specified pressure | bar | 64 (2) | 64 (2) |
Test values for ALB controller |
Number | Designation | MODEL 460 | |||
BE42.80-P-1001-01A | Output pressure of ALB controller (input pressure ALB controller 100 bar) with rear axle load (from 900 kg to 1500 kg) | 900 kg | Specified pressure | bar | 43 (2) |
1000 kg | Specified pressure | bar | 47 (2) | ||
1100 kg | Specified pressure | bar | 52 (2) | ||
1200 kg | Specified pressure | bar | 57 (2) | ||
1300 kg | Specified pressure | bar | 62 (2) |