Pneumatic brake system |
Number | Designation | Chassis 368.00/05/10/11/15; 382.07/08/11/12/15/17/18; 384.06/07/11/14/20/22/31/33; 634.001/011/012/014/061/071/081; 693.02/10/12/14/15/17/18/19/34/38; 694.00/02/04; 695.01/02/03/04/05; 695.30; 696.08/09; 696.36 | Chassis 364, 384.08/09, 386, 388, 397, 660, 664, 682, 688 | ||
BE42.60-B-1001-01A | Pressure regulator | Opening pressure - Wabco/Knorr | bar | 9,8 ... 10,2 | 7,9 ... 8,3 |
Closing pressure - Wabco/Knorr | bar | 8,7 ... 9,3 | 6,9 ... 7,7 | ||
Service pressure - Wabco/Knorr | bar | 13 | 12 | ||
Opening pressure of safety valve - Wabco/Knorr | bar | 14,5 ... 17,0 | 12,0 ... 15,0 | ||
Tires filling safety valve opening pressure - Wabco | bar | - | 9,0 ... 13,0 | ||
Admissible leakage - Wabco/Knorr | bar (menor ou igual cm3) | 10 | 10 | ||
Pressure on the test stand feeding circuit - Wabco/Knorr | bar | 15 | 10 | ||
Pressure applied to the port 1 for leak test - Wabco/Knorr | bar | 10 | 7 | ||
Pressure applied on the port 21 for leak test - Wabco/Knorr | bar | 10 | 7 | ||
BE42.60-B-1002-01A | Protective valve | Opening pressure - Wabco/Knorr - circuits 21 and 22 | bar | 8,7 ... 9,0 | 6,7 ... 7,0 |
Opening pressure - Wabco/Knorr - circuits 23, 24, 25 and 26 | bar | 7,2 ... 7,5 | 6,7 ... 7,0 | ||
Limiting valve opening pressure - Wabco - circuits 23, 24, 25 and 26 | bar | 8,1 ... 8,5 | - | ||
Closing pressure - Knorr - Circuits 21 and 22 | bar | 6,3 | - | ||
Closing pressure - Knorr - Circuits 23, 24, 25 and 26 | bar | 4,5 | - | ||
Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco/Knorr - Circuits 21 and 22 | bar | 7,0 | 4,5 ... 5,0 | ||
Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco - Circuits 23, 24, 25 and 26) | bar | 4,5 | - | ||
Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23, 24, 25 and 26 | bar | 5,5 | - | ||
Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23 and 24 | bar (maior ou igual) | - | 6,7 | ||
Pressure limit - Wabco/Knorr - Circuits 23, 24, 25 and 26 | bar | 8,1 ... 8,5 | - | ||
Safety valve opening pressure - Knorr - Circuits 23, 24, 25 and 26 | bar (maior de) | 8,2 | - | ||
Safety valve opening pressure - Knorr - Circuits 23, 24 | bar (maior ou igual) | - | 5,0 | ||
Pressure reduction (cut-in pressure) - Knorr - Circuits 21 and 22 | bar | 10,4 ... 10,6 | - | ||
Pressure reduction (cut-in pressure) - Knorr - Circuits 23 and 24 | bar | 8,4 ... 8,6 | - | ||
Pressure reduction (shifting range) - Knorr - Circuits 21, 22, 23 and 24 | bar (maior ou igual) | 0,5 | - | ||
Admissible leakage - Wabco | bar (menor ou igual cm3/min) | 10,0 | 10,0 | ||
Admissible leakage - Knorr | bar | 8,0 | - | ||
Bench feeding circuit pressure - Wabco | bar | 15,0 | - | ||
Bench feeding circuit pressure - Knorr | bar | 11,8 ... 12,2 | 9,0 | ||
Pressure during the leak test - Wabco | bar | 10,0 | 8,0 | ||
Dynamic safety pressure - Knorr - Circuits 21, 22, 23 and 24 | bar (maior ou igual) | - | 5,0 |
Pneumatic brake system |
Number | Designation | Chassis 979.046 | ||
BE42.60-B-1001-01A | Pressure regulator | Opening pressure - Wabco/Knorr | bar | 7,9 ... 8,3 |
Closing pressure - Wabco/Knorr | bar | 6,9 ... 7,8 | ||
Service pressure - Wabco/Knorr | bar | 13 | ||
Opening pressure of safety valve - Wabco/Knorr | bar | 14,5 ... 17 | ||
Tires filling safety valve opening pressure - Wabco | bar | - | ||
Admissible leakage - Wabco/Knorr | bar (menor ou igual cm3) | 10 | ||
Pressure on the test stand feeding circuit - Wabco/Knorr | bar | 15 | ||
Pressure applied to the port 1 for leak test - Wabco/Knorr | bar | 10 | ||
Pressure applied on the port 21 for leak test - Wabco/Knorr | bar | 10 | ||
BE42.60-B-1002-01A | Protective valve | Opening pressure - Wabco/Knorr - circuits 21 and 22 | bar | 6,7 ... 7,0 |
Opening pressure - Wabco/Knorr - circuits 23, 24, 25 and 26 | bar | 6,7 | ||
Limiting valve opening pressure - Wabco - circuits 23, 24, 25 and 26 | bar | - | ||
Closing pressure - Knorr - Circuits 21 and 22 | bar | - | ||
Closing pressure - Knorr - Circuits 23, 24, 25 and 26 | bar | - | ||
Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco/Knorr - Circuits 21 and 22 | bar | 4,5 ... 5,0 | ||
Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco - Circuits 23, 24, 25 and 26) | bar | - | ||
Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23, 24, 25 and 26 | bar | - | ||
Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23 and 24 | bar (maior ou igual) | 6,7 | ||
Pressure limit - Wabco/Knorr - Circuits 23, 24, 25 and 26 | bar | - | ||
Safety valve opening pressure - Knorr - Circuits 23, 24, 25 and 26 | bar (maior de) | - | ||
Safety valve opening pressure - Knorr - Circuits 23, 24 | bar (maior ou igual) | 5,0 | ||
Pressure reduction (cut-in pressure) - Knorr - Circuits 21 and 22 | bar | - | ||
Pressure reduction (cut-in pressure) - Knorr - Circuits 23 and 24 | bar | - | ||
Pressure reduction (shifting range) - Knorr - Circuits 21, 22, 23 and 24 | bar (maior ou igual) | - | ||
Admissible leakage - Wabco | bar (menor ou igual cm3/min) | 10,0 | ||
Admissible leakage - Knorr | bar | - | ||
Bench feeding circuit pressure - Wabco | bar | - | ||
Bench feeding circuit pressure - Knorr | bar | 9,0 | ||
Pressure during the leak test - Wabco | bar | 8,0 | ||
Dynamic safety pressure - Knorr - Circuits 21, 22, 23 and 24 | bar (maior ou igual) | 5,0 |