Rear air conditioning |
Number | Designation | MODEL 903.663 with A/C SC1-9, SC4-10 | MODEL 904.663, with SC1-9, SC2-10, SC3-10, SC4-10, air conditioning SC5-10 | ||
BA83.50-N-1001-01E | Connector for refrigerant lines | Thrust side | Nm | 35 | 35 |
Intake side | Nm | 35 | 35 | ||
BA83.50-N-1002-01E | Mounting nut, fluid reservoir to housing of roof air conditioning | Nm | – | 10 | |
BA83.50-N-1003-01E | Mounting bolt, refrigerant line to refrigerant compressor | Nm | 18 | 18 | |
BA83.50-N-1004-01E | Mounting bolt, underfloor condenser to bracket | Nm | – | – | |
BA83.50-N-1005-01E | Mounting bolt, filter drier to body | Nm | 10 | 10 | |
BA83.50-N-1006-01E | Bolt, refrigerant line to filter drier | Nm | 8 | 8 | |
BA83.50-N-1007-01E | Nut, connection for refrigerant pressure capillary tube | Nm | 10 | 10 | |
BA83.50-N-1008-01E | Bolt, refrigerant line to expansion valve | Nm | 8 | 8 | |
BA83.50-N-1009-01E | Bolt, expansion valve to vaporizer tube | Nm | 8 | 8 | |
BA83.50-N-1010-01E | Pressure switch to refrigerant line | Nm | 10 | 10 | |
BA83.50-N-1011-01E | Bolt, evaporator unit to vehicle roof | Nm | 20 | 20 | |
BA83.50-N-1012-01E | Line connection to expansion valve | Nm | – | – | |
BA83.50-N-1013-01E | Line connection to filter drier | Nm | – | – | |
BA83.50-N-1014-01E | Bolt, mounting clamp of filter drier | Nm | – | – | |
BA83.50-N-1015-01E | Line connection to inspection glass | Nm | – | – | |
BA83.50-N-1016-01E | Condenser fan mounting bolt | Nm | – | – |
Rear air conditioning |
Number | Designation | MODEL 904.663, 905.613, with SC3-11 air conditioning with auxiliary condenser | MODEL 904.663, 905.613, with roof air conditioning, Sütrak AC 111 | ||
BA83.50-N-1001-01E | Connector for refrigerant lines | Thrust side | Nm | 35 | 35 |
Intake side | Nm | 35 | 35 | ||
BA83.50-N-1002-01E | Mounting nut, fluid reservoir to housing of roof air conditioning | Nm | – | 10 | |
BA83.50-N-1003-01E | Mounting bolt, refrigerant line to refrigerant compressor | Nm | 18 | 18 | |
BA83.50-N-1004-01E | Mounting bolt, underfloor condenser to bracket | Nm | 10 | – | |
BA83.50-N-1005-01E | Mounting bolt, filter drier to body | Nm | 10 | – | |
BA83.50-N-1006-01E | Bolt, refrigerant line to filter drier | Nm | 8 | – | |
BA83.50-N-1007-01E | Nut, connection for refrigerant pressure capillary tube | Nm | 10 | 10 | |
BA83.50-N-1008-01E | Bolt, refrigerant line to expansion valve | Nm | 8 | – | |
BA83.50-N-1009-01E | Bolt, expansion valve to vaporizer tube | Nm | 8 | – | |
BA83.50-N-1010-01E | Pressure switch to refrigerant line | Nm | 10 | 10 | |
BA83.50-N-1011-01E | Bolt, evaporator unit to vehicle roof | Nm | 20 | – | |
BA83.50-N-1012-01E | Line connection to expansion valve | Nm | – | – | |
BA83.50-N-1013-01E | Line connection to filter drier | Nm | – | – | |
BA83.50-N-1014-01E | Bolt, mounting clamp of filter drier | Nm | – | – | |
BA83.50-N-1015-01E | Line connection to inspection glass | Nm | – | – | |
BA83.50-N-1016-01E | Condenser fan mounting bolt | Nm | – | – |
Rear air conditioning |
Number | Designation | MODEL 905.613 with Hispacold roof air conditioning D5 | ||
BA83.50-N-1001-01E | Connector for refrigerant lines | Thrust side | Nm | 45 |
Intake side | Nm | 45 | ||
BA83.50-N-1002-01E | Mounting nut, fluid reservoir to housing of roof air conditioning | Nm | – | |
BA83.50-N-1003-01E | Mounting bolt, refrigerant line to refrigerant compressor | Nm | 18 | |
BA83.50-N-1004-01E | Mounting bolt, underfloor condenser to bracket | Nm | – | |
BA83.50-N-1005-01E | Mounting bolt, filter drier to body | Nm | – | |
BA83.50-N-1006-01E | Bolt, refrigerant line to filter drier | Nm | – | |
BA83.50-N-1007-01E | Nut, connection for refrigerant pressure capillary tube | Nm | – | |
BA83.50-N-1008-01E | Bolt, refrigerant line to expansion valve | Nm | – | |
BA83.50-N-1009-01E | Bolt, expansion valve to vaporizer tube | Nm | – | |
BA83.50-N-1010-01E | Pressure switch to refrigerant line | Nm | 15 | |
BA83.50-N-1011-01E | Bolt, evaporator unit to vehicle roof | Nm | – | |
BA83.50-N-1012-01E | Line connection to expansion valve | Nm | 33 | |
BA83.50-N-1013-01E | Line connection to filter drier | Nm | 44 | |
BA83.50-N-1014-01E | Bolt, mounting clamp of filter drier | Nm | 16 | |
BA83.50-N-1015-01E | Line connection to inspection glass | Nm | 44 | |
BA83.50-N-1016-01E | Condenser fan mounting bolt | Nm | 8 |