Refrigerant lines |
Number | Designation | Model 405.05/09/10/11/12/20/22 | Model 405.21/23 | ||
BA83.30-N-1001-02C | Bolt, refrigerant line to desiccant cartridge | M6 | Nm | 7 | 7 |
BA83.30-N-1002-02C | Union nut, refrigerant line to desiccant cartridge | Nm | - | - | |
BA83.30-N-1003-02C | Bolt, refrigerant line to refrigerant line | M6 | Nm | 7 | - |
M8 | Nm | 18 | - | ||
BA83.30-N-1004-02C | Condenser to cooling module | - | - | ||
BA83.30-N-1005-02C | Union nut, refrigerant line to threaded fitting | Pipe Ø 10 mm | Nm | 16,5 | 16,5 |
Pipe Ø 16 mm | Nm | 25 | 25 | ||
Pipe Ø 18 mm | Nm | 42 | 42 | ||
BA83.30-N-1006-02C | Bolt, refrigerant line to expansion valve | M6 | Nm | 5,5 | - |
BA83.30-N-1007-02C | Bolt, expansion valve to retaining plate | M5 | Nm | 5,5 | - |
BA83.30-N-1008-02C | Screw, expansion valve to evaporator refrigerant line | M5 | Nm | - | - |
Refrigerant lines |
Number | Designation | MODEL 437.42/43 with CODEF56 | Model 437.4 | ||
BA83.30-N-1001-02C | Bolt, refrigerant line to desiccant cartridge | M6 | Nm | 7 | 7 |
BA83.30-N-1002-02C | Union nut, refrigerant line to desiccant cartridge | Nm | - | - | |
BA83.30-N-1003-02C | Bolt, refrigerant line to refrigerant line | M6 | Nm | - | 7 |
M8 | Nm | - | 18 | ||
BA83.30-N-1004-02C | Condenser to cooling module | - | 8 | ||
BA83.30-N-1005-02C | Union nut, refrigerant line to threaded fitting | Pipe Ø 10 mm | Nm | 16,5 | - |
Pipe Ø 16 mm | Nm | 25 | - | ||
Pipe Ø 18 mm | Nm | 42 | - | ||
BA83.30-N-1006-02C | Bolt, refrigerant line to expansion valve | M6 | Nm | - | 5,5 |
BA83.30-N-1007-02C | Bolt, expansion valve to retaining plate | M5 | Nm | - | - |
BA83.30-N-1008-02C | Screw, expansion valve to evaporator refrigerant line | M5 | Nm | - | 5,5 |
Refrigerant lines |
Number | Designation | MODEL 437.46 with CODE F56 | ||
BA83.30-N-1001-02C | Bolt, refrigerant line to desiccant cartridge | M6 | Nm | - |
BA83.30-N-1002-02C | Union nut, refrigerant line to desiccant cartridge | Nm | 20 | |
BA83.30-N-1003-02C | Bolt, refrigerant line to refrigerant line | M6 | Nm | - |
M8 | Nm | - | ||
BA83.30-N-1004-02C | Condenser to cooling module | - | ||
BA83.30-N-1005-02C | Union nut, refrigerant line to threaded fitting | Pipe Ø 10 mm | Nm | - |
Pipe Ø 16 mm | Nm | - | ||
Pipe Ø 18 mm | Nm | - | ||
BA83.30-N-1006-02C | Bolt, refrigerant line to expansion valve | M6 | Nm | - |
BA83.30-N-1007-02C | Bolt, expansion valve to retaining plate | M5 | Nm | - |
BA83.30-N-1008-02C | Screw, expansion valve to evaporator refrigerant line | M5 | Nm | - |