Model | 690.6, 901.6, 902.6, 903.6, 904.6, 905.6, 909 |
with code HH9 (Air conditioner, automatic heater control) | |
Model | 690.6, 903.6 |
with code HH6 (Air conditioning, roof equipment) | |
Model | 690 |
with code H06 (Air-conditioning system) | |
Model | 901.0/3/4, 902.0/3/4, 903.0/3/4, 904.0/3/4 |
with code H06 (Air-conditioning system) | |
Model | 901.6, 902.6, 903.6, 904.6, 909.8 |
with code H08 (Roof-mounted air conditioning system, reinforced) | |
Model | 901.6, 902.6, 903.6, 904.6 |
with code HH7 (Roof-mounted air conditioning system, basic) | |
Model | 903.672 |
with code HK2 (Air conditioning in rear with underfloor condenser) | |
Model | 904 |
with code HK1 (Regulated air conditioning, roof equipment) |
Refrigerant lines |
Number | Designation | Model 909.8 | Model 909 | |
BA83.30-N-1001-02A | Refrigerant line, refrigerant compressor/condenser to condenser | Nm | 33 | 33 |
BA83.30-N-1002-02A | Refrigerant line, refrigerant compressor/condenser to refrigerant compressor | Nm | – | – |
BA83.30-N-1003-02A | Refrigerant line, condenser/fluid reservoir to condenser | Nm | 17 | 17 |
BA83.30-N-1004-02A | Refrigerant line at fluid reservoir | Nm | – | – |
BA83.30-N-1005-02A | Refrigerant line, expansion valve/refrigerant compressor to refrigerant compressor | Nm | – | – |
BA83.30-N-1006-02A | Screw/bolt for refrigerant line connection on expansion valve | Nm | 5 (0,5) | 5 (0,5) |
BA83.30-N-1007-02A | Nut, refrigerant line connection to expansion valve | Nm | 10 (2) | 10 (2) |
BA83.30-N-1008-02A | Screw/bolt, refrigerant line connector block on evaporator | Nm | 5 (0,5) | 5 (0,5) |
BA83.30-N-1009-02A | Screw/bolt, refrigerant line on refrigerant compressor | Nm | 21 (2) | 21 (2) |
BA83.30-N-1010-02A | Screw/bolt, refrigerant line on fluid reservoir | Nm | 7,8 (1) | 7,8 (1) |
Refrigerant lines |
Number | Designation | Model 690 | Model 690.6, 903.6 | |
BA83.30-N-1001-02A | Refrigerant line, refrigerant compressor/condenser to condenser | Nm | 33 | 33 |
BA83.30-N-1002-02A | Refrigerant line, refrigerant compressor/condenser to refrigerant compressor | Nm | – | – |
BA83.30-N-1003-02A | Refrigerant line, condenser/fluid reservoir to condenser | Nm | 17 | 17 |
BA83.30-N-1004-02A | Refrigerant line at fluid reservoir | Nm | 17 | – |
BA83.30-N-1005-02A | Refrigerant line, expansion valve/refrigerant compressor to refrigerant compressor | Nm | – | – |
BA83.30-N-1006-02A | Screw/bolt for refrigerant line connection on expansion valve | Nm | 5 | 5 (0,5) |
BA83.30-N-1007-02A | Nut, refrigerant line connection to expansion valve | Nm | 10 | 10 (2) |
BA83.30-N-1008-02A | Screw/bolt, refrigerant line connector block on evaporator | Nm | 5 | 5 (0,5) |
BA83.30-N-1009-02A | Screw/bolt, refrigerant line on refrigerant compressor | Nm | – | 21 (2) |
BA83.30-N-1010-02A | Screw/bolt, refrigerant line on fluid reservoir | Nm | – | 7,8 (1) |
Refrigerant lines |
Number | Designation | Model 901.0/3/4, 902.0/3/4, 903.0/3/4, 904.0/3/4 | Model 901.6, 902.6, 903.6, 904.6, 905.6 | |
BA83.30-N-1001-02A | Refrigerant line, refrigerant compressor/condenser to condenser | Nm | 33 (4) | 33 |
BA83.30-N-1002-02A | Refrigerant line, refrigerant compressor/condenser to refrigerant compressor | Nm | 33 (4) | – |
BA83.30-N-1003-02A | Refrigerant line, condenser/fluid reservoir to condenser | Nm | 17 (3) | 17 |
BA83.30-N-1004-02A | Refrigerant line at fluid reservoir | Nm | 17 (3) | – |
BA83.30-N-1005-02A | Refrigerant line, expansion valve/refrigerant compressor to refrigerant compressor | Nm | 44 (4) | – |
BA83.30-N-1006-02A | Screw/bolt for refrigerant line connection on expansion valve | Nm | 5 (-0,5/+1) | 5 (0,5) |
BA83.30-N-1007-02A | Nut, refrigerant line connection to expansion valve | Nm | 10 (2) | 10 (2) |
BA83.30-N-1008-02A | Screw/bolt, refrigerant line connector block on evaporator | Nm | 5 (-0,5/+1) | 5 (0,5) |
BA83.30-N-1009-02A | Screw/bolt, refrigerant line on refrigerant compressor | Nm | 23 (2,3) | 21 (2) |
BA83.30-N-1010-02A | Screw/bolt, refrigerant line on fluid reservoir | Nm | – | 7,8 (1) |
Refrigerant lines |
Number | Designation | Model 903.672 | Model 904 | |
BA83.30-N-1001-02A | Refrigerant line, refrigerant compressor/condenser to condenser | Nm | 16 | 33 |
BA83.30-N-1002-02A | Refrigerant line, refrigerant compressor/condenser to refrigerant compressor | Nm | – | – |
BA83.30-N-1003-02A | Refrigerant line, condenser/fluid reservoir to condenser | Nm | 16 | 17 |
BA83.30-N-1004-02A | Refrigerant line at fluid reservoir | Nm | – | – |
BA83.30-N-1005-02A | Refrigerant line, expansion valve/refrigerant compressor to refrigerant compressor | Nm | – | – |
BA83.30-N-1006-02A | Screw/bolt for refrigerant line connection on expansion valve | Nm | 5 | 5 (0,5) |
BA83.30-N-1007-02A | Nut, refrigerant line connection to expansion valve | Nm | 10 | 10 (2) |
BA83.30-N-1008-02A | Screw/bolt, refrigerant line connector block on evaporator | Nm | 5 | 5 (0,5) |
BA83.30-N-1009-02A | Screw/bolt, refrigerant line on refrigerant compressor | Nm | 21 | 21 (2) |
BA83.30-N-1010-02A | Screw/bolt, refrigerant line on fluid reservoir | Nm | 8 | 7,8 (1) |
Refrigerant lines |
Number | Designation | Model 901.6, 902.6, 903.6, 904.6 | |
BA83.30-N-1001-02A | Refrigerant line, refrigerant compressor/condenser to condenser | Nm | 33 |
BA83.30-N-1002-02A | Refrigerant line, refrigerant compressor/condenser to refrigerant compressor | Nm | – |
BA83.30-N-1003-02A | Refrigerant line, condenser/fluid reservoir to condenser | Nm | 17 |
BA83.30-N-1004-02A | Refrigerant line at fluid reservoir | Nm | – |
BA83.30-N-1005-02A | Refrigerant line, expansion valve/refrigerant compressor to refrigerant compressor | Nm | – |
BA83.30-N-1006-02A | Screw/bolt for refrigerant line connection on expansion valve | Nm | 5 (0,5) |
BA83.30-N-1007-02A | Nut, refrigerant line connection to expansion valve | Nm | 10 (2) |
BA83.30-N-1008-02A | Screw/bolt, refrigerant line connector block on evaporator | Nm | 5 (0,5) |
BA83.30-N-1009-02A | Screw/bolt, refrigerant line on refrigerant compressor | Nm | 21 (2) |
BA83.30-N-1010-02A | Screw/bolt, refrigerant line on fluid reservoir | Nm | 7,8 (1) |