Mount for front module crossmember and longitudinal member at the front, right and left |
N97.20-2002-06
N97.20-2005-09
Left and right engine compartment, crossmember under the windshield | Engine compartment firewall and reinforcement firewall at the front, lower left and right |
N97.20-2015-08
Area to the side of A-pillar, at the front, lower left and right |
N97.20-2017-08
Area of lower B-pillar and longitudinal member outer shell on right and left sliding door entrance |
N97.20-2019-07
Area of sliding door entrance on the outer right and left |
N97.20-2021-09
Area of sidewall paneling lower section and wheel arch to rear, left and right |
N97.20-2024-09
Area of sidewall paneling side, lower section and roof frame panel | Lower side piece to rear, left and right |
N97.20-2029-08
End crossmember inner part |
N97.20-2031-09
End crossmember external part |
Rear corner paneling with right and left shock absorber mount |
N97.20-2034-06
Rear roof frame |
N97.20-2037-06
Area of left and right front door |
N97.20-2038-12
N97.20-2039-08
Area of liftgate | Area of right and left rear-end door |
Picture no., etc. | Work notes | ||
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Danger | Risk of explosion and poisoning caused by solvent vapors and gasses. Risk of injury to skin and eyes when working with anticorrosion agents | Never spray corrosion protection on flames or hot, glowing objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection. | |
Topical note | Notes on cavity preservation | ||
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
| Processing instructions for cavity preservation agent | ||
Apply wax from inside in crosshatched areas following sealing and paintwork, however, before performing assembly work. | Insert spray hoses as far as possible into hollow cavities. | ||
Carry out repair preservation twice successively with a flash-off time of 5 min between the processes. | The spraying hose should be stiff and the nozzles should spray at angle to the front and rear. | ||
After drying, ensure that drain holes are not plugged. | The processing temperature should not be less than +15°C. | ||
Rivets that are not sealed with seam sealant must be treated with wax. |