D97.20-0009-05
Engine hood
Driver/passenger door
D97.20-0010-03
D97.20-0012-02
Sliding door
Hinged rear door
D97.20-0011-03
D97.20-0008-06
Waistrail
D97.20-0004-07
Left and right front longitudinal member
D97.20-0015-08
Left door sill
D97.20-0018-09
A-pillar, complete side wall with roof frame and cross bow
D97.20-0016-06
B, C-pillar and sliding door entry
D97.20-0017-06
Corner pillars, rear roof frame and end crossmember
D97.20-0013-09
Entire underbody
Danger! | Risk of explosion and poisoning caused by solvent vapors and gasses. Risk of injury to skin and eyes when working with anticorrosion agents | Never spray anticorrosion agents on flames or glowing hot objects and keep them well away from all potential sources of ignition. Use them only in well-ventilated rooms; wear respiratory protection. | |
| Notes on cavity preservation | ||
1 | Perform repair preservation | The processing temperature should not be less than 15 °C. Additional preservation measures may be required depending on the repair area deviating from the standard cavity preservation illustrated. | |
Apply cavity preservation agent in marked areas only after completing sealing and paintwork, however, before assembly work from inside. Apply repair preservation agent twice with a drying time of 5 minutes in between. | |||
Perform cavity preservation, as required by repair area and on adjacent areas, over large surface. | |||
The spraying hose should be stiff and the nozzles should spray at angle to the front and rear. The cavities should be dry. | |||
Insert spray hoses as far as possible into cavities. Spray while inserting and pulling out slowly. | |||
Combination spray gun (corrosion protection) gotis://K_91-97_01.0 | |||
Cavity preservation | |||
| Cavity protection, general | ||
2 | Remove cavity sealant from drain holes |
Repair materials
Number | Designation | Order number |
BR00.45-Z-1003-05A | Cavity sealant, solvent-free (1 l container) | A 000 986 72 70 05 |