1 | Electrical line |
2 | Cable grommet |
3 | Cylinder shell at bottom |
4 | Screw/bolt |
5 | Safety clip |
A13 | Auxiliary heater (ZHE) control unit |
W83.70-1506-11
6 | Electrical connectors |
A13 | Auxiliary heater (ZHE) control unit |
W83.70-1507-11
| Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Disconnect electrical connector for warm air auxiliary heater unit | Do not interrupt the power supply in heating mode or during the run-on phase. | |
2 | Remove cylinder shell at top | ||
3 | Remove electrical line (1) with cable grommet (2) from cylinder shell at bottom (3) | ||
4 | Remove screw/bolt (4) | Screw/bolt, auxiliary heater control unit to combustion and hot air blower housing | |
5 | Press safety clip (5) together and remove auxiliary heater (ZHE) control unit (A13) | ||
6 | Disconnect electrical connectors (6) from auxiliary heater (ZHE) control unit (A13) | The electrical connectors (6) are coded and cannot be swapped. | |
7 | Install in the reverse order | ||
8 | Check warm air auxiliary heater unit for proper operation | See operator's manual for warm air auxiliary heater unit. |