Shown on MODEL 222 |
1 | Stationary heater fuel pump |
2 | Fuel hose |
3 | Electrical connector |
4 | Bracket |
P83.70-5531-12
Danger ! | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
| Remove/install | ||
1 | Release right rear underfloor paneling | ||
Lift right rear underfloor paneling to side until stationary heater fuel pump (1) is accessible. | |||
2 | Disconnect electrical connector (3) | ||
3 | Pinch off fuel hoses (2) | Clamp | |
4 | Detach fuel hoses (2) from stationary heater fuel pump (1) | Replace snap clamps. | |
Collect fuel which runs out in a suitable container. | |||
Pliers for click clamps | |||
5 | Detach stationary heater fuel pump (1) from bracket (4) | Installation: Note direction of installation of stationary heater fuel pump (1). | |
6 | Install in the reverse order |
000 589 40 37 00
Clamp
171 589 00 37 00
Pliers for click clamps