ar8370d5652a

Removing and installing fuel metering pump

ประเภท ar · หัวข้อ 83.70 · เวอร์ชัน 0104 · 1998-07-31

ใช้กับ: MODEL 902.32# /42#, 903.32# /42#, 904.32# /42# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater Heater designation D1L-C MODEL 903.02# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater Heater designation B1L-C

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — ซีรีส์ 902 (รุ่น 32*, 42*) · ซีรีส์ 903 (รุ่น 02*, 32*, 42*) · ซีรีส์ 904 (รุ่น 32*, 42*)

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.46 Pump/container — ซีรีส์ 902 (รุ่น 32*, 42*) · ซีรีส์ 903 (รุ่น 02*, 32*, 42*) · ซีรีส์ 904 (รุ่น 32*, 42*)

AR83.70-D-5652A

Removing and installing fuel metering pump

4.11.96

MODEL 902.32# /42#, 903.32# /42#, 904.32# /42# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater
Heater designation D1L-C

MODEL 903.02# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater
Heater designation B1L-C

Removing and installing fuel metering pump

D83.70-0017-06

1 Fuel line to fuel tank
2 Hose clamp
3 Fuel metering pump
4 Holder
5 Hose clamp
6 Fuel line to heater
7 Electrical connector
8 Electrical connector

Removal, installation

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation

Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Fuel vapors present an explosion hazard. Fuel vapors are toxic when inhaled or absorbed. Contact with fuel can cause eye and skin injury.

Fire, open lights and smoking prohibited.
Fill and store fuel only in containers intended for this purpose and marked accordingly.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

1

Loosen hose clamp (2) and pull off fuel hose (1)

Catch fuel running out.

2

Loosen hose clamp (5) and pull off fuel hose (6)

Catch fuel running out.

3

Disconnect electrical connectors (7, 8)

4

Remove fuel metering pump (3)

5

Install in opposite order

เอกสารที่อ้างถึง