ar8370d5302a

Removing and installing heater

ประเภท ar · หัวข้อ 83.70 · เวอร์ชัน 0105 · 2001-09-20

ใช้กับ: MODELS 902.32# /42#, 903.32# /42#, 904.32# /42# ## up to 753730 up to 31.10.97 with CODE (H11) Warm air auxiliary heater heater designation D1L-C MODEL 903.02# ## up to 753730 up to 31.10.97 with CODE (H11) Warm air auxiliary heater heater designation B1L-C

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — ซีรีส์ 902 (รุ่น 32*, 42*) · ซีรีส์ 903 (รุ่น 02*, 32*, 42*) · ซีรีส์ 904 (รุ่น 32*, 42*)

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.30 Heater — ซีรีส์ 902 (รุ่น 32*, 42*) · ซีรีส์ 903 (รุ่น 02*, 32*, 42*) · ซีรีส์ 904 (รุ่น 32*, 42*)

AR83.70-D-5302A

Removing and installing heater

4.11.96

MODELS 902.32# /42#, 903.32# /42#, 904.32# /42# ## up to 753730 up to 31.10.97 with CODE (H11) Warm air auxiliary heater
heater designation D1L-C

MODEL 903.02# ## up to 753730 up to 31.10.97 with CODE (H11) Warm air auxiliary heater
heater designation B1L-C

Removing and installing heater

D83.70-0018-06

1 Electrical connector

2 Electrical connector

3 Heater unit

4 Intake hose

5 Exhaust pipe

6 Clip

7 Gasket

8 Fuel pipe

9 Washer

10 Heater fastening nut

11 Hexagon nut

12 Sheet metal screw

13 Securing clamp

14 Securing clamp

Remove/install

Danger!

Risk of explosion from fuel vapors, risk of poisoning from inhaling combustion gases and risk of injury from burns during and after operation of heater unit.

Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves.

AS83.70-Z-0002-01A

1

Remove bench

2

Disconnect electrical connectors (1; 2)

3

Detach fastening clamp (13) for exhaust pipe (5)

Danger!

Risk of explosion if ignition takes place, risk of poisoning caused by inhaling fuel vapors or swallowing fuel as well as risk of injury to skin and eyes exposed to fuel.

No fire, sparks, open flames or smoking.
Pour fuels only into suitable and appropriately marked containers.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

4

Release hose clamp (6) and disconnect fuel line (8)

Collect fuel which flows out

5

Detach fastening clamp (14) for intake hose (4)

6

Unscrew fastening nuts (10) for heater (3), remove washers (9)

7

Lift out heater (3)

8

Remove gasket (7)

Installation: Replace gasket

9

Clean sealing surface

10

Install in the reverse order

เอกสารที่อ้างถึง