1 | Condenser |
2 | Screw |
3 | Fluid reservoir |
4 | O-rings |
W83.30-A003-05
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
| Remove | ||
1 | Remove condenser (1) and set down on a soft surface. | ||
2 | Remove bolt (2). | ||
3 | Remove refrigerant reservoir (3) from condenser (1). | If the refrigerant reservoir (3) cannot be removed, | |
| |||
release the refrigerant reservoir (3) using a brass drift and hammer from the connecting flange of the condenser (1). | |||
4 | Remove O-rings (4). | ||
| Install | ||
5 | Moisten and install new O-rings (4) with compressor oil. | ||
| Compressor oils (specification 362.0) | ||
| |||
6 | Insert refrigerant reservoir (3) into condenser (1) and push onto connecting flange of condenser (1). | ||
7 | Screw in bolt (2) and tighten. | Bolt, fluid reservoir to condenser | |
8 | Install condenser (1). | ||
If the refrigerant reservoir (3) is replaced, | |||
| |||
observe additional oil filling quantity after replacing the refrigerant reservoir (3). | |||
Additional oil filling quantity after replacing accumulator |