ar8330w6520h

Remove/install fluid reservoir

ประเภท ar · หัวข้อ 83.30 · เวอร์ชัน 0103 · 2016-04-04

ใช้กับ: Model 963, 964 with code D6F (Air-conditioning system) Model 963, 964 with code D6G (Automatic climate control) Model 963, 964 with code D6H (Auxiliary air-conditioning unit) Model 963 with code D6C (Auxiliary air conditioning, electric)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.30 Air conditioning — ซีรีส์ 963 · ซีรีส์ 964

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.41 Condenser/drier/gas cooler — ซีรีส์ 963 · ซีรีส์ 964

AR83.30-W-6520H

Remove/install fluid reservoir

18.03.2016

Model

963, 964

with code D6F (Air-conditioning system)

Model

963, 964

with code D6G (Automatic climate control)

Model

963, 964

with code D6H (Auxiliary air-conditioning unit)

Model

963

with code D6C (Auxiliary air conditioning, electric)

Remove/install fluid reservoir

W83.30-1149-08

1

Left entrance

3

Bolts

B33

Air conditioning pressure sensor

2

Fluid reservoir

4

Separation point

Remove/install fluid reservoir

5

Separation point

6

Charge air cooler

7

Radiator

W83.30-1150-11

Remove/install fluid reservoir

2

Fluid reservoir

4

Separation point

5

Separation point

8

Refrigerant lines

9

Clamps

B33

Air conditioning pressure sensor

W83.30-1151-11

Remove/install

Danger !

Risk of injury caused by body parts being pinched or crushed as cab is tilted

Ensure that no one is within the tilting range of the cab as it is being tilted. Always tilt the cab all the way to the end position and secure with the safety strut.

AS60.80-Z-0001-01A

Danger !

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Notes on tilting the cab

AH60.80-N-0003-01A

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

1

Drain air conditioning system

Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks

AR83.30-W-1760HA

2

Tilt cab

3

Detach refrigerant line at separating point (5)

Installation: : Replace sealing ring.

Bolt, separating point of refrigerant line

*BA83.30-N-1001-01H

4

Remove entrance at left (1)

5

Detach refrigerant line at separating point (4)

Installation: : Replace sealing ring.

Bolt, separating point of refrigerant line

*BA83.30-N-1001-01H

6

Disconnect electrical connector at air conditioning pressure sensor (B33)

7

Remove screws/bolts (3) and remove accumulator (2) with bracket and refrigerant lines (8)

8

Remove refrigerant lines (8) from accumulator (2)

Installation: : Replace sealing rings.

Bolt, refrigerant line to fluid reservoir

*BA83.30-N-1002-01H

9

Remove air conditioning pressure sensor (B33) at accumulator (2)

A/C pressure sensor to fluid reservoir

*BA83.30-N-1007-01H

10

Loosen clamps (9) and remove accumulator (2) at bracket

11

Install in the reverse order

Air conditioning

Number

Designation

Model 963, 964

BA83.30-N-1001-01H

Bolt, separating point of refrigerant line

Nm

18

Air conditioning

Number

Designation

Model 963, 964

BA83.30-N-1002-01H

Bolt, refrigerant line to fluid reservoir

Nm

18

Air conditioning

Number

Designation

Model 963, 964

BA83.30-N-1007-01H

A/C pressure sensor to fluid reservoir

Nm

10

เอกสารที่อ้างถึง