AR83.30-T-5460AA | Manually open and manually close electromagnetic shutoff valve | 26.2.04 |
MODELS NMB671.015 /020 /021 /030 /042 with CODE (HKA) Konvekta ACX 602 air conditioning with roof heater
MODELS NMB613.455 with CODE (HKB) Konvekta ACX 641 SAPTCO air conditioning without roof heater
MODELS NMB613.358 /388 with CODE (HKD) Konvekta ACX 640 air conditioning with roof heater
MODELS NMB613.455 with CODE (HKE) Konvekta ACX 642 air conditioning with roof heater
MODELS NMB613.358 /388 with CODE (HKF) Webasto Top 2002 Aerosphere air conditioning with roof heater
MODELS NMB613.367 with CODE (HKG) Konvekta ACX 623 air conditioning with roof heater
MODELS NMB671.030 with CODE (HKC) Sütrak AC 353 air conditioning without roof heater
T83.30-0087-02
Shown on model 671.042 using Konvekta ACX 602 air conditioning with roof heater code HKA
1 Nut
2 Solenoid
3 Shutoff valve
T83.30-0088-11
Shown on model 671.042 using Konvekta ACX 602 air conditioning with roof heater code HKA
2 Solenoid
3 Shutoff valve
4 Magnet
Danger! | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | ||
| Remove | ||
1 | Remove paneling above electromagnetic shutoff valve | Models 671.015/020/021/030/042 with Konvekta ACX 602 air conditioning with roof heater code HKA | |
Model 671.030 with Sütrak AC 353 air conditioning without roof heater code HKC Open only right paneling. | |||
Model 613.455 with Konvekta ACX 641 SAPTCO air conditioning without roof heater code HKB Remove only rear cover. | |||
Models 613.358/388 with Konvekta ACX 640 air conditioning with roof heater code HKD, Model 613.455 with Konvekta ACX 642 air conditioning without roof heater code HKE | |||
Models 613.358/388 with Webasto Top 2002 Aerosphere air conditioning with roof heater code HKF Open only left paneling. | |||
Model 613.367 with Konvekta ACX 623 air conditioning with roof heater code HKG Remove cover above filter drier. | |||
2 | Unscrew nut (1) | ||
3 | Remove solenoid (2) | ||
Open | |||
4 | Fasten suitable magnet (4) to shutoff valve (3) | By attaching a magnet (4), the shutoff valve (3) is opened. | |
Close | |||
5 | Remove magnet (4) from shutoff valve (3) | By removing the magnet (4), the shutoff valve (3) is closed. | |
| Install | ||
6 | Install solenoid (2) | ||
7 | Screw on nut (1) | ||
8 | Install paneling above the electromagnetic shutoff valve | Models 671.015/020/021/030/042 with Konvekta ACX 602 air conditioning with roof heater code HKA | |
Model 671.030 with Sütrak AC 353 air conditioning without roof heater code HKC | |||
Model 613.455 with Konvekta ACX 641 SAPTCO air conditioning without roof heater code HKB | |||
Models 613.358/388 with Konvekta ACX 640 air conditioning with roof heater code HKD, Model 613.455 with Konvekta ACX 642 air conditioning without roof heater code HKE | |||
Models 613.358/388 with Webasto Top 2002 Aerosphere air conditioning with roof heater code HKF | |||
Model 613.367 with Konvekta ACX 623 air conditioning with roof heater code HKG |