S83.30-4678-08
Shown on model 470 |
1 | Cover | 3 | Bracket | B14 | Outside temperature sensor | ||
2 | Screw | 4 | Electrical connector |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Remove cover (1). | ||
2 | Remove screw (2) and take off holder (3) with outside temperature sensor (B14). | Installation: Ensure correct seating of the bracket (3) in the crossmember. | |
3 | Disconnect electrical connection (4). | ||
4 | Unclip outside temperature sensor (B14) from holder (3). | Only when replacing the outside temperature sensor (B14). | |
5 | Install in the reverse order. | ||
| Check | ||
6 | Perform function check of outside temperature sensor (B14). | Only after replacing the outside temperature sensor (B14). |