ar8330p6521msa

Remove/install desiccant cartridge

ประเภท ar · หัวข้อ 83.30 · เวอร์ชัน 0102 · 2019-07-03

ใช้กับ: Model 257, 290 with engine 256

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.30 Air conditioning — ซีรีส์ 257 · ซีรีส์ 290

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.41 Condenser/drier/gas cooler — ซีรีส์ 257 · ซีรีส์ 290

ใช้กับเครื่องยนต์/เกียร์ด้วย: 256 ***

AR83.30-P-6521MSA

Remove/install desiccant cartridge

02.07.2019

Model

257, 290 with engine 256

Remove/install desiccant cartridge

Shown on model 257

12

Upper engine cover

13

Engine air intake duct

14

Cold air intake

15

Bolts

16

Cross member

P83.30-5153-06

Remove/install desiccant cartridge

P83.30-4932-09

3

Plug

8

Drier module bracket

4

Retaining ring

9

Drier module riser line

5

Bolt M12

10

Drier module filter housing

6

Drier head

11

Desiccant bag

7

Pin

Danger

Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 257 with engine 256
with code 2U8 (Refrigerant R-1234yf)

AS83.00-Z-0007-01A

Warning

Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 257 with engine 256
except code 2U8 (Refrigerant R-1234yf)

AS83.00-Z-0006-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling refrigerant R134a

Model 257 with engine 256
except code 2U8 (Refrigerant R-1234yf)

AH83.30-N-0003-01A

Notes on handling refrigerant R1234yf

Model 257 with engine 256
with code 2U8 (Refrigerant R-1234yf)

AH83.30-P-0003-02A

Remove/install

1

Discharge air conditioning system.

AR83.30-P-1760FR

2

Remove upper engine cover (12).

AR01.10-P-2405MSA

3

Remove engine air intake duct (13).

4

Remove retaining clips and remove cold air intake (14).

5

Drill out rivets of support plates of front bumper at the crossmember.

Commercially available devices/tools
drill
riveter

Remove drilling chips.

6

Remove screws of supports of front bumper.

7

Remove screws (15), remove retaining clips and remove crossmember (16).

M61

*BA00.10-P-1002-04A

M81

*BA00.10-P-1004-04A

8

Remove plug (3).

Model 290 with engine 256Plug to condenser

*BA83.30-P-1007-01S

Model 257 with engine 256Plug to condenser

*BA83.30-P-1008-01R

9

Remove circlip (4).

10

Screw in screw M12 (5) into drier head (6) and pull out drier head (6).

11

Remove drier module holder (8) at pin (7) using suitable pliers.

12

Remove drier module riser line (9) together with drier module filter housing (10).

Installation: If the packaging of a new desiccant bag (11) is damaged, do not install it.
Place new desiccant bag (11) onto drier module riser line (9).

13

Install in the reverse order.

Metric screws/bolts and nuts as per MBN 10 105, 10 143

Number

Designation

8.8

10.9

BA00.10-P-1002-04A

M61

Nm

9

13

Metric screws/bolts and nuts as per MBN 10 105, 10 143

Number

Designation

8.8

10.9

BA00.10-P-1004-04A

M81

Nm

23

33

Air conditioning

Number

Designation

Model 290

BA83.30-P-1007-01S

Plug to condenser

Nm

4

Air conditioning

Number

Designation

Model 257

BA83.30-P-1008-01R

Plug to condenser

Nm

4

เอกสารที่อ้างถึง