P83.30-5191-09
2 | Condenser | 6 | Drier head | 9 | Drier module riser line | ||
3 | Screw plug | 7 | Pin | 10 | Drier module filter housing | ||
4 | Retaining ring | 8 | Drier module bracket | 11 | Desiccant bag | ||
5 | Screw |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R1234yf | |||
| Remove/install | ||
1 | Expose condenser (2) until screw plug (3) at condenser (2) is accessible. | Model 118, 177, 247 with engine 260, 282 | |
Model 118, 177, 247 with engine 282 | |||
Model 118, 177, 247 with engine 260 | |||
Secure condenser (2) against falling down. | |||
2 | Remove screw plug (3) at condenser (2). | Plug to condenser | |
3 | Remove circlip (4). | ||
4 | Screw screw (5) into drier head (6) and remove drier head (6). | ||
5 | Remove drier module holder (8) at pin (7) using suitable pliers. | ||
6 | Remove drier module riser line (9) together with drier module filter housing (10). | If the packaging of the new desiccant bag (11) is damaged, it may not be installed. | |
Installation: Apply new desiccant bag (11) on drier module riser line (9). | |||
7 | Install in the reverse order. |