ar8330p6521lf

Remove/install desiccant cartridge

ประเภท ar · หัวข้อ 83.30 · เวอร์ชัน 0105 · 2019-07-03

ใช้กับ: Model 217, 222 except code 1U6 (R744 refrigerant)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.30 Air conditioning — ซีรีส์ 217 · ซีรีส์ 222

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.41 Condenser/drier/gas cooler — ซีรีส์ 217 · ซีรีส์ 222

AR83.30-P-6521LF

Remove/install desiccant cartridge

02.07.2019

Model

217, 222

except code 1U6 (R744 refrigerant)

Remove/install desiccant cartridge

P83.30-4892-09

Shown on model 222 with code P20 (Driving Assistance Package Plus)

1

Reinforcement

5

Retaining clips

2

Sealing

6

Bolts

3

Engine air intake ducts

7

Electrical connector

4

Hood release cable

B29

Front long-range radar sensor

Remove/install desiccant cartridge

P83.30-4968-09

Shown on model 217 with code 610 (Night View Assist) and code P20 (Driving Assistance Plus Package)

1

Reinforcement

17

Radiator guides

6

Bolts

18

Spray nozzle

7

Electrical connector

B29

Front long-range radar sensor

7.1

Electrical connector

B84/11

Night View Assist infrared camera 2

Remove/install desiccant cartridge

Shown on model 222

8

Drier cap

9

Retaining ring

10

Pin

11

Drier head

12

Drier module riser line

13

Desiccant bag

16

Drier module bracket

P83.30-4893-06

Danger

Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 217, 222
with code 2U8 (Alternative refrigerant)
except code 1U6 (R744 refrigerant)

AS83.00-Z-0007-01A

Warning

Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 217, 222
except code 1U6 (R744 refrigerant)
except code 2U8 (Alternative refrigerant)

AS83.00-Z-0006-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling refrigerant R1234yf

Model 217, 222
with code 2U8 (Alternative refrigerant)
except code 1U6 (R744 refrigerant)

AH83.30-P-0003-02A

Notes on handling refrigerant R134a

Model 217, 222
except code 1U6 (R744 refrigerant)
except code 2U8 (Alternative refrigerant)

AH83.30-N-0003-01A

Remove

1

Drain air conditioning system

AR83.30-P-1760LF

2

Detach sealing (2) in area of front module

3

Remove engine intake air ducts (3)

Depending on the engine involved, only one engine air intake duct (3) is installed.

4.1

Remove front bumper

Model 217
except code 1U6 (R744 refrigerant)

AR88.20-P-2000LC

4.2

Remove radiator grille

Model 222
except code 1U6 (R744 refrigerant)

AR88.40-P-4001LF

5

Open retaining clips (5) and unhook hood release cable (4)

6

Release and disconnect electrical connector (7) from front long range radar sensor (B29)

Model 217, 222
with code P20 (Driving Assistance package Plus)
except code 1U6 (R744 refrigerant)

7

Release and disconnect electrical connector (7.1) from infrared camera for 2 Night View Assist (B84/11)

Model 217, 222
with code 610 (Night view assist)
except code 1U6 (R744 refrigerant)

8

Unclip spray nozzle (18) from infrared camera for 2 Night View Assist (B84/11)

Model 217, 222
with code 610 (Night view assist)
except code 1U6 (R744 refrigerant)

9

Remove bolts (6) from reinforcement (1)

10

Remove reinforcement (1) with upper radiator guides (17)

11

Unscrew drier cap (8)

12

Remove circlip (9)

13

Screw bolt M12 into drier head (11) and pull out drier head (11)

14

Use pliers to pull out drier module bracket (16) at pin (10)

Install

15

Apply new desiccant bag (13) on drier module riser line (12)

If the packaging of the new desiccant bag (13) is damaged, do not install it.

16

Install drier module bracket (16) with new desiccant bag (13)

17

Remove bolt M12 from drier head (11)

18

Install retaining ring (9)

19

Screw in drier cap (8)

20

Install reinforcement (1) with upper radiator guides (17)

21

Tighten bolts (6) on reinforcement (1)

22

Clip in spray nozzle (18) for infrared camera for 2 Night View Assist (B84/11)

Model 217, 222
with code 610 (Night view assist)
except code 1U6 (R744 refrigerant)

23

Plug electrical connector (7.1) onto infrared camera for 2 Night View Assist (B84/11) until it locks in to place

Model 217, 222
with code 610 (Night view assist)
except code 1U6 (R744 refrigerant)

24

Plug electrical connector (7) onto front long range radar sensor (B29) until it locks into place

Model 217, 222
with code P20 (Driving Assistance package Plus)
except code 1U6 (R744 refrigerant)

25

Clip hood release cable (4) into retaining clips (5) and close retaining clips (5)

26.1

Install radiator trim

Model 222
except code 1U6 (R744 refrigerant)

AR88.40-P-4001LF

26.2

Install front bumper

Model 217
except code 1U6 (R744 refrigerant)

AR88.20-P-2000LC

27

Install engine air intake ducts (3)

Depending on the engine involved, only one engine air intake duct (3) is installed.

28

Install sealing (2)

29

Fill air conditioning system

AR83.30-P-1760LF

30

Perform initialization of front long range radar sensor  (B29) using a diagnostic system

Model 217, 222
with code P20 (Driving Assistance package Plus)
except code 1U6 (R744 refrigerant)

AD00.00-P-2000-04B

31

Check air conditioning for proper operation

เอกสารที่อ้างถึง