ar8330p5520tx

Remove and install expansion valve

ประเภท ar · หัวข้อ 83.30 · เวอร์ชัน 0100 · 2006-07-26

ใช้กับ: MODEL 219.3

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.30 Air conditioning — ซีรีส์ 219 (รุ่น 3**)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.13 Line/hose/valve — ซีรีส์ 219 (รุ่น 3**)

AR83.30-P-5520TX

Remove and install expansion valve

13.9.04

MODEL 219.3

Remove and install expansion valve

P83.30-4073-09

1 Expansion valve

2 Cover

3 Nut

7 Bolts

8 Connection cables

9 Retaining plate

4 Low pressure pipe

5 Nut

6 High pressure pipe

Remove/install

1

Discharge air conditioning system

Installation: Evacuate, refill air conditioning system and check for proper operation and tightness.

AR83.30-P-1760TX

2

Remove wiper system

AR82.30-P-6400TX

3

Fold covering (2) upwards until the expansion valve (1) is accessible

4

Unscrew nut (3)

*BA83.30-P-1003-01H

5

Detach low-pressure line (4) and use suitable stop plug to seal opening of low-pressure line (4)

The opening of the low-pressure line (4) must be sealed, as otherwise penetrating dirt and moisture can damage the components connected to the refrigerant circuit.

Installation: Renew sealing ring of low-pressure line (4) and wet with compressor oil.

*WH58.30-Z-1002-27A

6

Unscrew nut (5)

*BA83.30-P-1004-01H

7

Detach high pressure line (6) and use suitable sealing cap to seal opening of high pressure line (6)

The opening of the high pressure line (6) must be sealed, as otherwise penetrating dirt and moisture can damage the components connected to the refrigerant circuit.

Installation: Renew sealing ring of high-pressure line (6) and wet with compressor oil.

*WH58.30-Z-1002-27A

8

Remove bolts (7)

Screw in screws (7) alternately, to avoid any tilting of the expansion valve (1).

Installation: Moisten threads of screws (7) using compressor oil.
Pull retaining plate (9) forward with pulling hook, hold in place and screw in screws (7).

*BA83.30-P-1005-01H

*140589023300

9

Remove expansion valve (1) and seal connecting lines (8) using suitable caps

The openings of the connecting lines (8) must be sealed, as otherwise penetrating dirt and moisture can damage the components connected to the refrigerant circuit.

Installation: Replace sealing rings of connecting lines (8) and wet with compressor oil.

*WH58.30-Z-1002-27A

10

Install in the reverse sequence

Air conditioning system

Number

Designation

Model 219

BA83.30-P-1003-01H

Nut for low-pressure line to high-pressure line

Nm

10

BA83.30-P-1004-01H

Nut for high-pressure line to expansion valve

Nm

10

BA83.30-P-1005-01H

Bolt, expansion valve to retaining plate

Nm

5

Remove and install expansion valve

Pulling hook

140 589 02 33 00

Commercially available tools

Number

Designation

WH58.30-Z-1002-27A

Set of plugs for air conditioning system

140 830 01 27

เอกสารที่อ้างถึง