ar8330p5520gh

Remove/install expansion valve

ประเภท ar · หัวข้อ 83.30 · เวอร์ชัน 0105 · 2010-02-02

ใช้กับ: MODEL 163.113 /128 /136 /154 /157 /172 /174 /175 with CODE (580) Air conditioning (or Tempmatic for USA)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.30 Air conditioning — ซีรีส์ 163 (รุ่น 113, 128, 136, 154, 157, 172, 174, 175)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.13 Line/hose/valve — ซีรีส์ 163 (รุ่น 113, 128, 136, 154, 157, 172, 174, 175)

AR83.30-P-5520GH

Remove/install expansion valve

19.1.10

MODEL 163.113 /128 /136 /154 /157 /172 /174 /175 with CODE (580) Air conditioning (or Tempmatic for USA)

Remove/install expansion valve

P83.30-0751-09

1 Expansion reservoir nuts

2 Expansion reservoir

3 Self-locking nut

7 Bolts

8 Sealing rings

9 Expansion valve bracket to evaporator

4 Pipelines bracket

5 Pipelines mounting clamps

6 Expansion valve

Remove/install

Danger!

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged.

AS83.00-Z-0001-01A

Procedure for a damaged or leaky air conditioning system

All models

AH83.30-N-0004-01A

Protect air conditioning circuit and components from moisture when carrying out repair work

All models with air conditioning

AH83.30-N-0005-01A

Notes on handling R134a refrigerant

All models with air conditioning

AH83.30-N-0003-01A

1

Discharge air conditioning system

Installation: Evacuate, refill air conditioning system and check for proper operation and tightness.

AR83.30-P-1760GH

2

Remove expansion reservoir nuts (1)

Place expansion reservoir to one side.

3

Remove pipelines bracket (4) from expansion valve (6)

Installation: Replace self-locking nut (3).

*BA83.30-P-1003-01B

4

Detach pipelines mounting clamps (5) from firewall

5

Pull both pipelines out of expansion valve (6)

Press pipelines to one side.

6

Remove screws/bolts (7) from expansion valve (6)

*BA83.30-P-1004-01B

7

Remove expansion valve (6)

Installation: Replace sealing rings and moisten with compressor oil.

8

Install in the reverse order

Air conditioning

Number

Designation

Model 163

BA83.30-P-1003-01B

Nut to pipeline on expansion valve

Nm

10

BA83.30-P-1004-01B

Nut securing expansion valve to evaporator

Nm

10

เอกสารที่อ้างถึง