Adapter kit
1 | Attach adapter (9) to connecting point - refrigerant compressor refrigerant line (E). |
2 | Connect high-pressure line (HP) of air conditioning service unit (30) to adapter (9). |
3 | Install adapter (4) in place of expansion valve. |
4 | Attach evaporator - connecting point refrigerant line (D) and evaporator - fluid reservoir refrigerant line (C) to adapter (4). |
5 | Install two adapters (3) in place of fluid reservoir (24). |
6 | Connect both adapters (3) with hose (12). |
7 | Attach adapter (10) to refrigerant compressor - condenser block refrigerant line (A). |
8 | Connect low-pressure line (LP) of air conditioning service unit (30) with adapter (10). |
9 | Start flushing procedure. |
When operating the air conditioning service unit (30), proceed in accordance with the operator's manual from the manufacturer. |
10 | Remove adapter (3, 4, 10). |
P83.30-4832-06