AR83.30-D-6520B | Remove/install fluid reservoir | 16.3.01 |
MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HH9) Automatic air conditioning "Tempmatic"
MODEL WD1, WD2, WD3, WD6, WD7
MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (HH9) Automatic air conditioning "Tempmatic"
MODEL 690.6 with CODE (HH9) Automatic air conditioning "Tempmatic"
D83.30-1113-12
1 Refrigerant line for expansion valve
2 Fluid reservoir
3 Refrigerant line for condenser
4 Screw clamp
6 Electrical connection lead for pressure switch
| Remove/Install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
1 | Discharge air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
2 | Disconnect electrical connection lead (6) from pressure switch | ||
3 | Unscrew refrigerant lines (1 and 3) | | |
4 | Loosen screw clamp (4) | ||
5 | Remove fluid reservoir (2) from bracket | ||
6 | Install in the reverse order | ||
7 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak. |
Refrigerant lines