1 | Bolts |
A40/3 | COMAND operating, display and control unit |
P82.85-2004-02
P82.85-2003-02
| Remove/install | ||
1 | Connect no-load current retention unit | ||
Commercially available devices/tools | |||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
2 | Disconnect battery ground line | ||
Topical note | Notes on battery | ||
3 | Remove cover on center console | ||
4 | Remove screws (1) and pull out COMAND operating, display and controller unit (A40/3) | Use screwdrivers with magnetic tip for screws that are poorly accessible. | |
5 | Disconnect electrical connectors | ||
6 | Install in the reverse order |