ar7721p080302mfa

Prepare front fixed element of panoramic sliding sunroof for installation

ประเภท ar · หัวข้อ 77.21 · เวอร์ชัน 0104 · 2019-12-23

ใช้กับ: Model 118, 177 with code 413 (Panoramic sliding sunroof/glass roof)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 77 Sliding roof, soft top, top attachments › 77.21 Panoramic roof — ซีรีส์ 118 · ซีรีส์ 177

EinPAS 38 Roof system › 38.15 Sliding roof/panoramic sliding sunroof › 38.15.33 Paneling/sliding roof panel — ซีรีส์ 118 · ซีรีส์ 177

AR77.21-P-0803-02MFA

Prepare front fixed element of panoramic sliding sunroof for installation

Topical note

Notes on removal/installation of bonded elements of panoramic roof

AH77.21-P-0001-01A

Model

118, 177

with code 413 (Panoramic sliding sunroof/glass roof)

Test and adjustment values for windshield

Number

Designation

Model 118

Model 177

BE67.10-P-1001-02C

Distance between top edge of window and front edge of roof/sliding roof aperture panel

Dimension "A"

mm

2,5 (1)

2,5 (1)

Prepare front fixed element of panoramic sliding sunroof for installation

129 589 03 21 00

Feeler gauge

Repair materials

Number

Designation

Order number

BR00.45-Z-1062-02A

Adhesive fabric tape

A 007 989 28 85

Prepare front fixed element of panoramic sliding sunroof for installation

1

Mount front fixed element (1) on body and align the clearance between windshield upper edge and roof front edge/sliding sunroof frame using the feeler gauge. 


Center front fixed element (1) between side roof panelings and windshield.


Observe installation position of windshield seal (arrow).


Helper required.



2

The Glue on tape strips and cut through at front edge of front fixed element (1).


P77.21-2607-06

Prepare front fixed element of panoramic sliding sunroof for installation

3

Set down front fixed element (1), with inside facing upwards, on a suitable base.



4

Clean bonding surfaces at front fixed element (1).


The cleaner is included in the repair kit.


Only apply cleaner to bonding surfaces and allow to fully dry.


It is not necessary to prime the bonding surfaces.



5

Apply activator to bonding surfaces at front fixed element (1).


The activator is included in the repair kit.


P77.21-2606-04