ประเภท ar · หัวข้อ 72.29 · เวอร์ชัน 0101 · 2013-05-13
ใช้กับ: MODEL 374.5/6, 375.3/4, 930, 932, 933, 934, 940, 942, 943, 944, 950, 952, 953, 954, 958.2/4 with CODE FZ3 (Extended central locking, with remote control) MODEL 375.1, 958.0, 970, 972, 974, 975, 976 with CODE FZ3 (Extended central locking, with remote control) MODEL 963, 964 with CODE F8F (Extended central locking) MODEL 967 with CODE F8F (Extended central locking)
Position test piece at top in center of window frame
Ensure that the test piece material cannot damage the window or window frame, e.g. a piece of corrugated hose. Align test body so that it cannot tip when hit by the side window.
4
Activate automatic side window closing feature and check anti-pinch protection on power window
The side window must reverse immediately when it hits the test body.
If anti-pinch protection is not OK:
Connect diagnostic system, start XENTRY and perform guided troubleshooting.