ar5410w0041a

Remove/install EMERGENCY OFF switch on right of frame

ประเภท ar · หัวข้อ 54.10 · เวอร์ชัน 0102 · 2012-02-22

ใช้กับ: MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (E06) Electrical system for hazardous goods vehicles (GGVS)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 54 Electrical system, equipment and instruments › 54.10 Battery, power supply, voltage converter — ซีรีส์ 942 (รุ่น 899) · ซีรีส์ 950 · ซีรีส์ 952 · ซีรีส์ 953 · ซีรีส์ 954

EinPAS 25 On-board/network/multifunction › 25.20 On-board electrical system › 25.20.12 Sensor/switch/wiring harness — ซีรีส์ 942 (รุ่น 899) · ซีรีส์ 950 · ซีรีส์ 952 · ซีรีส์ 953 · ซีรีส์ 954

AR54.10-W-0041A

Remove/install EMERGENCY OFF switch on right of frame

15.2.12

MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (E06) Electrical system for hazardous goods vehicles (GGVS)

Remove/install EMERGENCY OFF switch on right of frame

W54.10-0013-01

1 Securing bolts

2 Electrical line (to EMERGENCY OFF switch on right of frame)

3 Bracket (for EMERGENCY OFF switch on right of frame)

4 Gland screw connection

S109 Right frame EMERGENCY OFF switch

Remove/install

1

Switch off ignition

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

2

Disconnect ground lead from battery

Notes on battery

AH54.10-P-0001-01A

3

Loosen gland screw connection (4)

Installation: The gland screw connection (4) must close watertight.

4

Remove EMERGENCY OFF switch on right of frame (S109)

5

Open EMERGENCY OFF switch on right of frame (S109)

Installation: Pay attention to switch housing seal

6

Remove electrical line (2)

7

Install in the reverse order

8

Perform function test on electrical system

9

Set time on tachograph