ar5410s1129p

Check condition of battery

ประเภท ar · หัวข้อ 54.10 · เวอร์ชัน 0102 · 2020-01-10

ใช้กับ: Model 470, 471

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 54 Electrical system, equipment and instruments › 54.10 Battery, power supply, voltage converter — ซีรีส์ 470 · ซีรีส์ 471

EinPAS 25 On-board/network/multifunction › 25.20 On-board electrical system › 25.20.20 Battery — ซีรีส์ 470 · ซีรีส์ 471

AR54.10-S-1129P

Check condition of battery

09.01.2020

Model

470, 471

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

Check

1

Check on-board electrical system battery for external leakage or damage using visual check.

If a leakage or damage is present:

Replace on-board electrical system battery and dispose of properly.


AR54.10-S-0005P

2

Check on-board electrical system battery.

AR54.10-S-1129-01P

000 588 03 19 00 Load tester

WS15.00-P-0027B

000 588 02 19 00 Battery tester

WS54.00-N-3006B

If a defect is present:

Replace on-board electrical system battery and dispose of properly.


AR54.10-S-0005P

3

Detach ground line of on-board electrical system battery.

If "Surface voltage detected" message was previously shown in display of battery test device.

AR54.10-S-0003P

4

Reduce increased voltage after charging process.

If "Surface voltage detected" message was previously shown in display of battery test device.

AR54.10-S-1129-03P

000 588 03 19 00 Load tester

WS15.00-P-0027B

000 588 02 19 00 Battery tester

WS54.00-N-3006B

5

Connect ground line of on-board electrical system battery.

If the increased voltage was previously reduced.

AR54.10-S-0003P

6

Check on-board electrical system battery again.

If the increased voltage was previously reduced.

AR54.10-S-1129-01P

000 588 03 19 00 Load tester

WS15.00-P-0027B

000 588 02 19 00 Battery tester

WS54.00-N-3006B

7

Charge on-board electrical system battery.

If "Charge and check" message was previously shown in display of battery test device.

AR54.10-S-1130P

เอกสารที่อ้างถึง