ar5410p1130sr

Charge battery

ประเภท ar · หัวข้อ 54.10 · เวอร์ชัน 0301 · 2019-11-19

ใช้กับ: Model 453

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 54 Electrical system, equipment and instruments › 54.10 Battery, power supply, voltage converter — ซีรีส์ 453

EinPAS 25 On-board/network/multifunction › 25.20 On-board electrical system › 25.20.20 Battery — ซีรีส์ 453

AR54.10-P-1130SR

Charge battery

18.11.2019

Model

453

Modification notes

16.06.2017

"General information", inserted

Step 5

Charge battery

2

Charger positive terminal

3

Charger ground terminal

G1

On-board electrical system battery

P54.10-4055-11

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

Check

1

Open maintenance flap

With on-board electrical system battery (G1) installed.

2

Check installation position of vent hose and stop plugs of on-board electrical system battery (G1)

With on-board electrical system battery (G1) installed.

If a problem arises

Correct installation position of vent hose or stop plugs of on-board electrical system battery (G1).

3

Check condition of on-board electrical system battery (G1)

Not with on-board electrical system battery (G1) installed with active transport mode.

AR54.10-P-1129SR

Charging

4

Connect positive terminal for charger (2) to positive pole of on-board electrical system battery (G1) and ground clamp for charger (3) to negative pole of on-board electrical system battery (G1)

000 588 00 81 00 Charger

WS54.00-P-0037B


Do not reverse polarity.
Otherwise a short circuit will cause damage.

5

Charge on-board electrical system battery (G1)

Charge on-board electrical system battery (G1) using approved charger only.
The battery charging period depends on the charge level of the on-board electrical system battery (G1).
The on-board electrical system battery (G1) is sufficiently charged when the displayed charging current is  <  5  A.
Interrupt charging process when charging current undershoots 25 A during Midtronics test.

6

Switch off charger


Charger must be switched off before disconnecting.
Arcing can otherwise occur.

7

Disconnect positive terminal for charger (2) from positive pole of on-board electrical system battery (G1) and ground clamp for charger (3) from negative pole of on-board electrical system battery (G1) and close maintenance flap

Check

8

Check condition of on-board electrical system battery (G1)

Not with active transport mode.

AR54.10-P-1129SR

เอกสารที่อ้างถึง