ar5410p1129p

Check condition of battery

ประเภท ar · หัวข้อ 54.10 · เวอร์ชัน 0500 · 2020-01-30

ใช้กับ: Model 203, 209

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 54 Electrical system, equipment and instruments › 54.10 Battery, power supply, voltage converter — ซีรีส์ 203 · ซีรีส์ 209

EinPAS 25 On-board/network/multifunction › 25.20 On-board electrical system › 25.20.20 Battery — ซีรีส์ 203 · ซีรีส์ 209

AR54.10-P-1129P

Check condition of battery

20.01.2020

Model

203, 209

Modification notes

25.04.2007

Check fluid level for service fill level indicator incorporated

Operation step 3.2

10.05.2019

Battery capacity 70 Ah VRLA/AGM

BE54.10-P-1010-01A

Remove

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

1.1

Remove dust filter housing

Vehicles except code P98 (Black Series)

AP83.00-P-8381P

1.2

Remove cover of battery

Vehicles with code P98 (Black Series)

See

Disconnect/connect battery ground line
Model 209

AR54.10-P-0003Q

Check

2

Visual inspection for external leaks

If leakage found, replace battery:

Remove/install battery

AR54.10-P-0005P

3.1

Check fluid level in battery, replenish with distilled water if necessary

Without service fill level indicator, not on absorbent glass mat battery.

3.2

Check fluid level of battery

With service fill level indicator, not on absorbent glass mat battery.

Fluid level indicator via service fill level indicator, if color is white, the acid level is too low: Replace battery:

Remove/install battery

AR54.10-P-0005P

4

Check battery

AR54.10-P-1129-01A

Cold cranking amps as per EN

Commercially available devices/tools
Midtronics battery tester/test equipment with test clamps

Battery capacity 12 Ah

*BE54.10-P-1001-01A

Battery capacity 30 Ah

*BE54.10-P-1002-01A

Battery capacity 35 Ah

*BE54.10-P-1003-01A

Battery capacity 46 Ah

*BE54.10-P-1005-01A

Battery capacity 60 Ah VRLA/AGM

*BE54.10-P-1006-01A

Battery capacity 60 Ah

*BE54.10-P-1007-01A

Battery capacity 62 Ah

*BE54.10-P-1009-01A

Battery capacity 70 Ah VRLA/AGM

*BE54.10-P-1010-01A

Battery capacity 74 Ah

*BE54.10-P-1011-01A

Battery capacity 80 Ah VRLA/AGM

*BE54.10-P-1012-01A

Battery capacity 84 Ah

*BE54.10-P-1013-01A

Battery capacity 90 Ah VRLA

*BE54.10-P-1014-01A

Battery capacity 95 Ah VRLA

*BE54.10-P-1015-01A

Battery capacity 100 Ah

*BE54.10-P-1016-01A

5

Reduce increased voltage after charging process

On a battery that is disconnected from the on-board electrical system and with a "Surface voltage" message in the display of the Midtronics battery tester/test equipment.

AR54.10-P-1129-03A

After reducing increased voltage, test battery again.

Commercially available devices/tools
Midtronics battery tester/test equipment with test clamps

6

Charge battery

With the test code "Charge and check" on the Midtronics battery tester.

AR54.10-P-1130P

After charging, test battery again.

Install

7.1

Install dust filter housing

Vehicles except code P98 (Black Series)

S

AP83.00-P-8381P

7.2

Install cover of battery

Vehicles with code P98 (Black Series)

refer to:

Disconnect/connect battery ground line
Model 209

AR54.10-P-0003Q

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1001-01A

Battery capacity 12 Ah

Cold cranking amps

As per EN

A

170

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1002-01A

Battery capacity 30 Ah

Battery test at 20 °C

Acid density

kg/dm3

1,24

Maximum permissible difference between individual battery cells

kg/dm3

0,04

Load current

A

90

Load time

s

10

Voltage

V

10

Cold cranking amps

As per EN

A

540

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1003-01A

Battery capacity 35 Ah

Battery test at 20 °C

Acid density

kg/dm3

1,24

Maximum permissible difference between individual battery cells

kg/dm3

0,04

Load current

A

100

Load time

s

10

Voltage

V

10

Cold cranking amps

As per EN

A

520

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1005-01A

Battery capacity 46 Ah

Battery test at 20 °C

Acid density

kg/dm3

1,24

Maximum permissible difference between individual battery cells

kg/dm3

0,04

Load current

A

140

Load time

s

10

Voltage

V

10

Cold cranking amps

As per EN

A

420

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1006-01A

Battery capacity 60 Ah VRLA/AGM

Cold cranking amps

As per EN

A

660

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1007-01A

Battery capacity 60 Ah

Cold cranking amps

As per EN

A

510

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1009-01A

Battery capacity 62 Ah

Battery test at 20 °C

Acid density

kg/dm3

1,24

Maximum permissible difference between individual battery cells

kg/dm3

0,04

Load current

A

190

Load time

s

10

Voltage

V

10

Cold cranking amps

As per EN

A

480

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1010-01A

Battery capacity 70 Ah VRLA/AGM

Cold cranking amps

As per EN

A

720

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1011-01A

Battery capacity 74 Ah

Battery test at 20 °C

Acid density

kg/dm3

1,24

Maximum permissible difference between individual battery cells

kg/dm3

0,04

Load current

A

265

Load time

s

10

Voltage

V

10

Cold cranking amps

As per EN

A

680

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1012-01A

Battery capacity 80 Ah VRLA/AGM

Cold cranking amps

As per EN

A

800

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1013-01A

Battery capacity 84 Ah

Cold cranking amps

As per EN

A

700

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1014-01A

Battery capacity 90 Ah VRLA

Cold cranking amps

As per EN

A

950

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1015-01A

Battery capacity 95 Ah VRLA

Cold cranking amps

As per EN

A

850

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1016-01A

Battery capacity 100 Ah

Battery test at 20 °C

Acid density

kg/dm3

1,24

Maximum permissible difference between individual battery cells

kg/dm3

0,04

Load current

A

300

Load time

s

10

Voltage

V

10

Cold cranking amps

As per EN

A

760

เอกสารที่อ้างถึง