1 | Negative terminal |
2 | Ground cable |
3 | Positive terminal distributor |
4 | Positive terminal |
5 | Nuts |
6 | Screw |
7 | Bracket |
G1 | On-board electrical system battery |
P54.10-3974-04
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
| Remove/install | ||
1 | Loosen negative terminal (1) with ground line (2) and remove from on-board electrical system battery (G1) | ||
2 | Remove positive terminal cover | ||
3 | Unscrew nuts (5) from positive terminal distributor (3) and place positive terminal distributor (3) to one side | ||
4 | Loosen positive terminal (4) and remove from on-board electrical system battery (G1) | Nut, battery cable to negative terminal/positive terminal of on-board electrical system battery | |
5 | Remove screw/bolt (6) and remove bracket (7) | Bolt, battery bracket to body | |
6 | Disconnect vent hose from on-board electrical system battery (G1) | ||
7 | Remove on-board electrical system battery (G1) | Installation: | |
| |||
8 | Install in the reverse order | ||
9 | Reset clock | See Owner's Manual. |