ar5410d0111m

Remove/install additional battery for ECO start/stop function

ประเภท ar · หัวข้อ 54.10 · เวอร์ชัน 0101 · 2020-01-09

ใช้กับ: Model 906 with code MJ7 (ECO start/stop function) with code XM0 (Facelift)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 54 Electrical system, equipment and instruments › 54.10 Battery, power supply, voltage converter — ซีรีส์ 906

EinPAS 25 On-board/network/multifunction › 25.20 On-board electrical system › 25.20.20 Battery — ซีรีส์ 906

AR54.10-D-0111M

Remove/install additional battery for ECO start/stop function

08.01.2020

Model

906

with code MJ7 (ECO start/stop function)

with code XM0 (Facelift)

Remove/install additional battery for ECO start/stop function

1

Cover

2

Seat base

3

Relay holder

4

Nut

5

Bracket

6

Positive lines

7

Ground cable

G1/12

On-board electrical system backup battery

D54.10-1174-06

Remove/install

1

Switch off all electrical consumers


All electrical consumers must be switched off.
They may otherwise be damaged when the ground line (7) is disconnected/connected.

2

Switch off ignition and remove transmitter key from electronic ignition lock control unit

3

Remove driver seat

AR91.10-D-1010H

Do not remove seat belt from driver's seat.

4

Detach cover (1) from seat base (2)

Installation: Position electrical lines for driver's seat on cover (1).

5

Remove relay holder (3) from seat base (2) and swivel forward

6

Unscrew nut (4) from bracket (5)

7

Swing bracket (5) upwards and detach from battery holder

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

8

Disconnect ground line (7) from on-board electrical system backup battery (G1/12)

Topical note

Notes on battery

AH54.10-P-0001-01A

Check

9

Check power for on-board electrical system has been disabled

Using a diode test lamp, check the on-board electrical system for voltage between the positive terminal of the on-board electrical system backup battery (G1/12) and the disconnected ground line (7).
If the diode test lamp lights up, the on-board electrical system is still active because of a defect in the electrical system.

If diode test lamp lights up:

Detach ground line of on-board electrical system battery.


AR54.10-D-0003SD

The electrical system is to be repaired once the work to be carried out has been completed.

10

Disconnect positive lines (6) from on-board electrical system backup battery (G1/12)

11

Remove on-board electrical system backup battery (G1/12) from battery holder

12

Install in the reverse order

เอกสารที่อ้างถึง