AR54.10-D-0007SD | Remove/install additional battery | 15.2.12 |
MODEL 900, 906 with CODE (E28) 12 V 88 Ah additional battery
D54.10-1169-08
Shown on engine 646
1 Ground cable
2 Positive line
3 Bracket
G1/2 Additional battery
4 Bracket
5 Vent line
| Remove/install | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
| Notes on battery | ||
1 | Disconnect ground line (1) from additional battery (G1/2) | ||
2 | Disconnect positive line (2) from additional battery (G1/2) | ||
3 | Detach vent line (5) from additional battery (G1/2) | ||
4 | Remove bracket (3, 4) | ||
5 | Remove additional battery (G1/2) | Installation: Observe disposal regulations when replacing additional battery (G1/2). See: | |
| Dispose of battery | ||
6 | Install in the reverse order |