1 | Electrical connector |
2 | Electrical line |
3 | O-ring |
4 | AdBlue® tank |
5 | Temperature sensor |
6 | AdBlue® fill level and temperature sensor |
G49.20-3220-06
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Notes on use, material properties and handling of AdBlue® | |||
| Remove/install | ||
1 | Switch off ignition. | ||
2 | Disconnect electrical connector (1). | ||
3 | Expose electrical line (2). | ||
4 | Clean AdBlue® container (4) in the area of the AdBlue® fill level and temperature sensor (6). | | |
5 | Turn AdBlue® fill level and temperature sensor (6) clockwise and remove from the AdBlue® container (4). | If drips of AdBlue® get onto AdBlue® container (4), the resulting urea crystals can be removed with water and a lint-free dry cloth. | |
Installation: Check sealing ring (3) for wear and damage; replace if necessary. | |||
6 | Install in the reverse order. |