S47.70-A070-09
1 | High-voltage battery | 3 | Diagnostic unit | |
2 | Diagnostic system | 4 | Adapter cable |
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | Notes on battery | ||
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Preparatory tasks | |||
1 | Remove high-voltage battery (1). | ||
| Check | ||
2 | Attach ground strap of adapter cable (4) to housing of high-voltage battery (1). | Adapter cable | |
3 | Connect diagnostic unit (3) with adapter cable (4) to high-voltage battery (1). | ||
| 000 586 00 99 00 Battery diagnostic unit | ||
Adapter cable | |||
4 | Establish power supply for diagnostic unit (3). | ||
| 000 586 00 99 00 Battery diagnostic unit | ||
To do so, use power cable or 12 V voltage cable. | |||
5 | Establish power supply for the diagnostic system (2). | When XENTRY Kit is used, the diagnostic system (2) must be connected to the external power supply. | |
6 | Connect diagnostic system (2) with diagnostic unit (3). | ||
| 000 586 00 99 00 Battery diagnostic unit | ||
7 | Perform check of high-voltage battery (1) with diagnostic system (2). | ||
The operation steps must be performed exactly as per XENTRY Diagnosis Software. | |||
Select the following menu path: | |||
Do not clear fault memory when high-voltage battery (1) is removed. | |||
8 | Disconnect power supply for diagnostic unit (3). | ||
| 000 586 00 99 00 Battery diagnostic unit | ||
9 | Disconnect power supply for diagnostic system (2). | ||
10 | Remove ground strap of adapter cable (4) from housing of high-voltage battery (1). | Adapter cable | |
11 | Remove diagnostic unit (3) with adapter cable (4) from high-voltage battery (1). | ||
| 000 586 00 99 00 Battery diagnostic unit | ||
Adapter cable | |||
Concluding tasks | |||
12 | Install high-voltage battery (1). |
222 589 04 63 00
Adapter cable