AR42.60-W-0070A | Fill compressed-air reservoir with air from external source | 22.2.96 |
Model 374, 375.3 /4, 940, 942, 943, 944, 950, 952, 953, 954, 957, 958.2 /4
W42.10-0039-01
1 Screw plug
2 Filling hose
3 Filling connection
6.12 Single-chamber air drier with integral pressure regulator
W42.10-0040-01
1 | Unscrew screw plug (1) and screw in filling connection (3) | The filling connection (3) remains installed. | |
2 | Connect filling hose (2) to filling connection (3) | ||
3 | Connect filling hose (2) to external air source and fill compressed air reservoir | Only use connection 12 or (on vehicles with code (B56) Coupling head at front for air replenishment) the coupling head when filling from an external source. Compressed air reservoirs can be filled until the pressure regulator cutoff pressure is reached. |