Test and adjust the 4-circuit protection valve

ประเภท ar · หัวข้อ 42.60 · เวอร์ชัน 0100 · 2016-02-12

ใช้กับ:

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 42 Brakes - hydraulic and mechanical systems › 42.60 Pneumatic system — ซีรีส์ 364 · ซีรีส์ 384 · ซีรีส์ 386 · ซีรีส์ 688

EinPAS 21 Brakes/vacuum system/compressed-air system › 21.35 Compressed-air system › 21.35.13 Line/hose/valve — ซีรีส์ 364 · ซีรีส์ 384 · ซีรีส์ 386 · ซีรีส์ 688

AR42.60-B-0017-01A

Test and adjust the 4-circuit protection valve

Compressed air brake system

Número

Denominação

chassis 368.00/05/10/11/15; 382.07/08/12/15/17/18; 384.06/07/11/14/20/22/31/33; 634.001/011/061; 693.02/10/12/14/15/17/18/19/34/38; 694.00/02/04; 695.01/02/03/04/05; 695.30; 696.08/09; 696.36

BE42.60-B-1002-01A

Protective valve

Opening pressure - Wabco/Knorr - circuits 21 and 22

bar

8,7 ... 9,0

Opening pressure - Wabco/Knorr - circuits 23, 24, 25 and 26

bar

7,2 ... 7,5

Limiting valve opening pressure - Wabco - circuits 23, 24, 25 and 26

bar

8,1 ... 8,5

Closing pressure - Knorr - Circuits 21 and 22

bar

6,3

Closing pressure - Knorr - Circuits 23, 24, 25 and 26

bar

4,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco/Knorr - Circuits 21 and 22

bar

7,0

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco - Circuits 23, 24, 25 and 26)

bar

4,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23, 24, 25 and 26

bar

5,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23 and 24

bar (bigger or equal)

-

Pressure limit - Wabco/Knorr - Circuits 23, 24, 25 and 26

bar

8,1 ... 8,5

Safety valve opening pressure - Knorr - Circuits 23, 24, 25 and 26

bar (bigger than)

8,2

Safety valve opening pressure - Knorr - Circuits 23, 24

bar (bigger or equal)

-

Pressure reduction (shifting pressure) - Knorr - Circuits 21 and 22

bar

10,4 ... 10,6

Pressure reduction (shifting pressure) - Knorr - Circuits 23 and 24

bar

8,4 ... 8,6

Pressure reduction (shifting range) - Knorr - Circuits 21, 22, 23 and 24

bar (bigger or equal)

0,5

Admissible leakage - Wabco

bar (smaller or equal to cm3/min)

10,0

Admissible leakage - Knorr

bar

8,0

Bench feeding circuit pressure - Wabco

bar

15,0

Bench feeding circuit pressure - Knorr

bar

11,8 ... 12,2

Pressure during the tightness test - Wabco

bar

10,0

Dynamic safety pressure - Knorr - Circuits 21, 22, 23 and 24

bar (bigger or equal)

-

Produtos para reparos

Número

Denominação

Número de pedido

BR00.45-B-1002-02A

Chemical lock Loctite 271

Loctite 271

Test and adjust the 4-circuit protection valve

B42.60-0315-12

1 - Workbench accessories

A = Workbench pressure regulating valve.

G = Actuation valves arranged in all circuits.

a = Restriction of the supply circuit, 0.85 mm diameter.

F = Restrictions of the circuits 21; 22; 23; and 24, 0.35 mm diameter.

M1 = M21 = M22 = M23 = M24 = Pressure gages in the circuits. Nominal diameter of the pipe = 8 mm.

2 - Visual check

Check the valve for external damages.

3 - Connect the valve in test stand

Connection 1, in the supply circuit for pressurization through the valve “G”, restriction “a” and gage M1;

Connection 21, in the circuit of the gage M21 with de-pressurization through the valve “G” and valve “F”;

Connections 23 and 24, in the circuits of the respective gages M23 and M24 with de-pressurization through the valves “G” and restrictions “F”.

Test and adjust the 4-circuit protection valve

B42.60-0210-01

4 - Test the leak

Apply 8 bar in the circuit 1 through the valve “A” and restriction “F”.

Activate and deactivate the valve from 10 to 15 times for a better seating of the components.

Close the circuits 21; 22; 23 and 24 through the valves “G”.

Apply neutral soap foam and check for leaks.

Close the valve “G” supplying the circuit 1 keeping it pressurized.

The pressure in the circuit 1 may drop, at maximum 0.1 bar in 2 minutes. If leaks occur it is necessary to disassemble and repair the valve.

Pressure gages M21; M22; M23 and M24 must indicate zero bar.

Close the valves of the circuits 21; 22; 23; and 24.

5 -Adjust the opening pressure

Circuit 21

Apply 6.7 to 7.0 bar on circuit 1 through the regulating valve “A”, tap“G” and restriction “A”. Confirm the pressure on gage M1.

Loosen the“M” threaded pin corresponding to the circuit 21 until pressure increase starts on gage M21.

Circuit 22

Through the valve “G” and restriction “F” de-pressurize the circuit 21. The gage M21 will have to indicate zero bar.

Close the valve “G” of the circuit 21.

Apply 6.7 to 7.0 bar on circuit 1 through the valve “A”, tap“G” and restriction “a”. Confirm the pressure on gage M22.

Loosen the“M” adjusting threaded pin corresponding to the circuit 22 until pressure increase starts on gage M22.

Circuits 23 and 24

Note:To adjust the circuits 23 and 24, the valves of the circuits 21 and 22 are to be open with the beginning adjusting pressure. A pressure difference of approximately 0.2 more bar will occur for the circuits 23 and 24.

Through the valve "A", tap "G" and restriction "a" apply 6.7 to 7.0 bar on circuit 1. Confirm the pressures on gages M1; M21 and M22.

The valves of the circuits 21 and 22 must be open at the beginning of the adjusting pressure (6.7 to 7.0 bar).

Loosen the“M” adjusting threaded pin corresponding to the circuit 23 until pressure increase starts on gage M23.

Loosen the“M” adjusting threaded pin corresponding to the circuit 24 until pressure increase starts on gage M24.

6 - Test the closing and safety pressure

Close the valves of the circuits 21; 22; 23 and 24.

Through the valve "A", tap "G" and restriction "A" apply to 8 bar on circuit 1. Confirm the pressures on gages of the circuits.

Close the valve “G” of the circuit 1 supply.

Through the valve “G” and restriction “F” de-pressurize the circuit 23. Pressure gages M21; M22; and M24, must indicate a pressure not below 4.5 bar.

Close the valve “G” of the circuit 23.

Pressurize the circuit 1 through the valve “A” and tap “G” and restriction “a”. Confirm the pressures on the circuit gages.

Close the valve “G” of the circuit 1 supply.

Through the valve “G” and restriction “F” de-pressurize the circuit 24. Pressure gages M21; M22; and M23 must indicate a pressure not below 4.5 bar.

Close the valve “G” of the circuit 24.

Pressurize the circuit 1 to 8 bar through the valve “A” ,tap “G” and restriction “a”. Confirm the pressures on the circuit gages.

De-pressurize the circuits 1 and 21 through the valves “G” and restrictions “F”. The gage M22 will have to indicate a pressure not below 4.5 bar and the gages M23 and M24 a pressure not below 6.7 bar.

Close the valves “G” de-pressurizing the circuits 1 and 21.

Pressurize the circuit 1 to 8 bar through the valve “A” ,tap “G” and restriction “a”. Confirm the pressures on the circuit gages.

De-pressurize the circuits 1 and 22 through the valves “G” and restrictions “F”. The gage M21 will have to indicate a pressure not below 4.5 bar and the gages 23 and 24 and a pressure not below 6.7 bar.

De-pressurize all the circuits through the valves “G” and restrictions “F”.

7 - Lock the threaded adjusting

Once the valve test and adjustment are finished, lock the threaded “M” pins applying one or two drops of a specified locking compound in its top part.

8 - Remove the valve from the test stand

Remove the connections from the valve and install plastic protectors in the ports.