1 | Electrical connector |
2 | Screw |
A25 | Electronic Stability Program (ESP®) control unit |
W42.45-1078-12
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on self-locking nuts and bolts | ||
Notes on safety-relevant components | |||
| Remove/install | ||
1 | Switch off ignition. | ||
2 | Disconnect electrical connector (1) from Electronic Stability Program (ESP®) control unit (A25). | ||
3 | Remove bolts (2) . | Electronic Stability Program (ESP®) control unit to crossmember or bracket | |
4 | Remove Electronic Stability Program (ESP®) control unit (A25) from holder. | ||
5 | Install in the reverse order. | ||
6 | Teach in Electronic Stability Program (ESP®) control unit (A25). | Only if the Electronic Stability Program (ESP®) control unit (A25) has been replaced. | |