Measurement of angle 4 at rear axle differential
An angle that has already been measured can be measured a second time if required. Here, with the Measurement menu displayed, press the STEP button repeatedly until the display shows it is ready to measure the relevant angle.
1.1 | On rear axle differentials (3) with contact surfaces (4). |
Remove any unevenness on surface of material using a suitable tool. |
1.2 | On rear axle differentials (3) without contact surfaces (4). |
P41.10-2392-01
2.1 | On rear axle differentials (3) with contact surfaces (4). |
When each measurement is taken, the side of the sensor (020a) at which the spiral cable (020b) is connected must point in the direction of travel. |
2.2 | On rear axle differentials (3) without contact surfaces (4). |
When each measurement is taken, the side of the sensor (020a) at which the spiral cable (020b) is connected must point in the direction of travel. |
P41.10-2393-01
The meter is ready to take a measurement. The display shows the measured values.
3 | Press SAVE button. |
The device saves the values. |
Measurement value display message angle piece 4: Display, e.g. 2.68° |
P41.10-2082-01
A confirmation message appears briefly, followed by Ready for next measurement (angle 5). The measurement is completed and stored in memory.
Display message confirmation |
P41.10-2076-01
4.1 | On rear axle differential (3) with contact surfaces (4). |
4.2 | On rear axle differentials (3) without contact surfaces (4). |
P41.10-2393-01
5.1 | On rear axle differentials (3) with contact surfaces (4). |
5.2 | On rear axle differentials (3) without contact surfaces (4). |
P41.10-2392-01