B32.20-0125-09
4 | Auxiliary axle | 10 | Bracket for lift bellows | |
7 | Regulation nuts | C | Adjusting measurement (with depressurized shaft) | |
9 | Self-locking nuts |
Topical note | Notes on self-locking nuts and bolts | ||
| Remove | ||
1 | Remove the brackets for lift bellows (10) self-locking nuts (9) | | |
| Check | ||
2 | Check the conditions of the brackets for lift bellows (10) and adjusting nuts (7) | Always replace the self-locking nuts (10). | |
In case the brackets for lift bellows (10) and the adjusting nuts (7) are in good conditions and are reused: | |||
| |||
Do not move the adjusting nuts (7) as they will be the basis for adjusting the measure (C). | |||
| Install | ||
3 | Install the adjusting nuts (7) to the brackets for lift bellows (10) | If the components are new | |
4 | Install the brackets for lift bellows (10) securing with adjusting nuts (9) | Do not apply the prescribed torque. | |
5 | Adjust measure "C" between the brackets for lift bellows (10) and the auxiliary axle (4) | ||
Adjustment measure between the bellows arch and the auxiliary shaft | |||
6 | Apply the tightening torque to the fixing nuts (9) | Upper nut for locking the bellows arch |