366 589 00 21 05
Extension
001 589 53 21 00
Dial gage
363 589 02 21 00
Dial indicator holder
Check |
1 | Secure dial indicator (2) with dial indicator holder (1) and extension (3) to bell hub. |
2 | Mount dial indicator point on the drive shaft with approx. 1 mm preload and position dial indicator to zero. |
3 | Press against shim (4) and move drive shaft toward wheel hub and axle center alternately using an assembly lever (arrow) while reading off axial play of drive shaft from dial indicator. |
The axial play must be adjusted if there are deviations from the specified value. |
Adjust
4 | Adjust axial play of drive shaft with appropriate shim (4). |
W33.20-0012-01