1 | Transfer case |
4 | Electrical connector |
5 | Bolts |
B57 | Transfer case absolute sensor |
P33.00-2152-06
Danger | Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Lift vehicle with lifting platform. | ||
Topical note | Special instructions for lifting and supporting vehicle | ||
2 | Release and disconnect electrical connector (4) of absolute sensor transfer case (B57). | ||
3 | Remove screws (5). | Screw/bolt, absolute sensor to transfer case | |
4 | Remove absolute sensor transfer case (B57). | Installation: | |
5 | Install in the reverse order. | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
6 | Perform engine test run; while doing so check transfer case (1) for proper operation. |